lm565c National Semiconductor Corporation, lm565c Datasheet
lm565c
Available stocks
Related parts for lm565c
lm565c Summary of contents
Page 1
... LM565/LM565C Phase Locked Loop General Description The LM565 and LM565C are general purpose phase locked loops containing a stable, highly linear voltage controlled os- cillator for low distortion FM demodulation, and a double bal- anced phase detector with good carrier suppression. The VCO frequency is set with an external resistor and capacitor, and a tuning range of 10:1 can be obtained with the same capacitor ...
Page 2
... Note 2: The maximum junction temperature of the LM565 and LM565C is +150˚C. For operation at elevated temperatures, devices in the TO-5 package must be derated based on a thermal resistance of +150˚C/W junction to ambient or +45˚C/W junction to case. Thermal resistance of the dual-in-line package is +85˚C/W. ...
Page 3
Typical Performance Characteristics Power Supply Current as a Function of Supply Voltage DS007853-14 Oscillator Output Waveforms DS007853-17 Loop Gain vs Load Resistance DS007853-20 Lock Range as a Function of Input Voltage DS007853-15 Phase Shift vs Frequency DS007853-18 Hold in Range ...
Page 4
Schematic Diagram www.national.com 4 ...
Page 5
AC Test Circuit Note: S open for output offset voltage (V − measurement Typical Applications 2400 Hz Synchronous AM Demodulator DS007853-6 5 DS007853-5 www.national.com ...
Page 6
Typical Applications (Continued) www.national.com FSK Demodulator (2025–2225 cps) FSK Demodulator with DC Restoration 6 DS007853-7 DS007853-8 ...
Page 7
Typical Applications (Continued) Frequency Multiplier (x10) IRIG Channel 13 Demodulator 7 DS007853-9 DS007853-10 www.national.com ...
Page 8
Applications Information In designing with phase locked loops such as the LM565, the important parameters of interest are: FREE RUNNING FREQUENCY LOOP GAIN: relates the amount of phase change between the input signal and the VCO signal for a shift ...
Page 9
Applications Information (Continued) Damping Time Constant vs Natural Frequency DS007853-14 Capacitor C should be much smaller than C 2 tion is to provide filtering of carrier. In general C 9 since its func www.national.com ...
Page 10
... Physical Dimensions inches (millimeters) unless otherwise noted www.national.com Metal Can Package (H) Order Number LM565H NS Package Number H10C Dual-In-Line Package (N) Order Number LM565CN NS Package Number N14A 10 ...
Page 11
... NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF NATIONAL SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant ...