hcpl-7800a-300 ETC-unknow, hcpl-7800a-300 Datasheet - Page 16

no-image

hcpl-7800a-300

Manufacturer Part Number
hcpl-7800a-300
Description
High Isolation Amplifiers
Manufacturer
ETC-unknow
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
hcpl-7800a-300E
Manufacturer:
IR
Quantity:
3 000
Part Number:
hcpl-7800a-300E
Manufacturer:
AVAGO
Quantity:
26 000
Part Number:
hcpl-7800a-300E
Manufacturer:
AVAGO
Quantity:
8 000
ISO-AMP
conflicting considerations,
therefore, must be weighed
against each other in selecting an
appropriate sense resistor for a
particular application. To
maintain circuit accuracy, it is
recommended that the sense
resistor and the isolation amplifier
circuit be located as close as
possible to one another. Although
it is possible to buy current-
sensing resistors from established
vendors (e.g., the LVR-1, -3 and
-5 resistors from Dale), it is also
possible to make a sense resistor
using a short piece of wire or
even a trace on a PC board.
Figure 28. HCPL-7800 Block Diagram.
Figure 29. PC Board Trace Pattern and Loading Diagram Example.
INPUT
MODULATOR
REGULATOR
VOLTAGE
GENERATOR
ENCODER
CLOCK
Figures 30 and 31 illustrate the
response of the overall isolation
amplifier circuit shown in Figure
26. Figure 30 shows the response
of the circuit to a
kHz sine wave input and Figure
31 the response of the circuit to a
input. Both figures demonstrate
the fast, well-behaved response of
the HCPL-7800.
Figure 32 shows how quickly the
isolation amplifier recovers from
an overdrive condition generated
by a 2 kHz square wave swinging
between 0 and 500 mV (note that
200 mV 20 kHz square wave
LED DRIVE
CIRCUIT
BOUNDARY
ISOLATION
200 mV 20
DETECTOR
CIRCUIT
REGULATOR
VOLTAGE
DECODER
AND D/A
the time scale is different from
the previous figures). The first
wave form is the output of the
application circuit with the filter
capacitors removed to show the
actual response of the isolation
amplifier. The second wave form
is the response of the same circuit
with the capacitors installed. The
recovery time and overshoot are
relatively independent of the
amplitude and polarity of the
overdrive signal, as well as its
duration.
For more information, refer to
Application Note 1059.
FILTER
1-231
ISO-AMP
OUTPUT

Related parts for hcpl-7800a-300