m29dw324d Numonyx, m29dw324d Datasheet - Page 11

no-image

m29dw324d

Manufacturer Part Number
m29dw324d
Description
32 Mbit 4mb X8 Or 2mb X16, Dual Bank 16 16, Boot Block 3v Supply Flash Memory
Manufacturer
Numonyx
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
m29dw324dB
Manufacturer:
YAGEO
Quantity:
210 000
Part Number:
m29dw324dB
Manufacturer:
ST
0
Part Number:
m29dw324dB-70N6
Manufacturer:
ST
Quantity:
8 680
Part Number:
m29dw324dB-70N6
Manufacturer:
CY
Quantity:
9 691
Part Number:
m29dw324dB-70N6
Manufacturer:
ST
0
Part Number:
m29dw324dB-70N6E
Manufacturer:
ST
0
Part Number:
m29dw324dB70N1E
Manufacturer:
ST
0
Part Number:
m29dw324dB70N6
Manufacturer:
ST
Quantity:
8 670
Part Number:
m29dw324dB70N6
Manufacturer:
ST
0
operation. During Program or Erase operations
Ready/Busy is Low, V
pedance during Read mode, Auto Select mode
and Erase Suspend mode.
After a Hardware Reset, Bus Read and Bus Write
operations cannot begin until Ready/Busy be-
comes high-impedance. See
Block Temporary Unprotect AC Characteristics
and
AC
The use of an open-drain output allows the Ready/
Busy pins from several memories to be connected
to a single pull-up resistor. A Low will then indicate
that one, or more, of the memories is busy.
Byte/Word Organization Select (BYTE). The
Byte/Word Organization Select pin is used to
switch between the x8 and x16 Bus modes of the
memory. When Byte/Word Organization Select is
Low, V
High, V
Waveforms.
Figure 16., Reset/Block Temporary Unprotect
IL
IH
, the memory is in x8 mode, when it is
, the memory is in x16 mode.
OL
. Ready/Busy is high-im-
Table 19., Reset/
V
vides the power supply for all operations (Read,
Program and Erase).
The Command Interface is disabled when the V
Supply Voltage is less than the Lockout Voltage,
V
cidentally damaging the data during power up,
power down and power surges. If the Program/
Erase Controller is programming or erasing during
this time then the operation aborts and the memo-
ry contents being altered will be invalid.
A 0.1µF capacitor should be connected between
the V
pin to decouple the current surges from the power
supply. The PCB track widths must be sufficient to
carry the currents required during Program and
Erase operations, I
V
measurements. The device features two V
which must be both connected to the system
ground.
CC
LKO
SS
Ground. V
Supply Voltage (2.7V to 3.6V). V
. This prevents Bus Write operations from ac-
CC
Supply Voltage pin and the V
M29DW324DT, M29DW324DB
SS
CC3
is the reference for all voltage
.
SS
CC
Ground
SS
11/50
pins
pro-
CC

Related parts for m29dw324d