n25q032 Numonyx, n25q032 Datasheet - Page 47

no-image

n25q032

Manufacturer Part Number
n25q032
Description
32-mbit 3 V, Multiple I/o, 4-kbyte Subsector Erase, Xip Enabled, Serial Flash Memory With 108 Mhz Spi Bus Interface
Manufacturer
Numonyx
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
n25q03213
Manufacturer:
ST
0
Part Number:
n25q03213E40
Manufacturer:
MICRON
Quantity:
20 000
Part Number:
n25q032A11EF440E
Manufacturer:
MICRON/美光
Quantity:
20 000
Part Number:
n25q032A11EF640E
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
n25q032A11EF640E
Manufacturer:
MICRON/美光
Quantity:
20 000
Part Number:
n25q032A11EF640F
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
n25q032A11EF640F
Manufacturer:
MICRON
Quantity:
20 000
Company:
Part Number:
n25q032A11EF640F
Quantity:
20 000
Part Number:
n25q032A11ESE40
Manufacturer:
ST
0
Part Number:
n25q032A11ESE40F
Manufacturer:
ST
0
Part Number:
n25q032A11ESE40F
Manufacturer:
MICRON/美光
Quantity:
20 000
Part Number:
n25q032A13E1240E
Manufacturer:
MICRON
Quantity:
210
Part Number:
n25q032A13E1240F
Manufacturer:
MICRON
Quantity:
210
Company:
Part Number:
n25q032A13E1240F
Quantity:
110
Part Number:
n25q032A13E1241E
Manufacturer:
MICRON
Quantity:
5 000
Table 9.
0
0
1
1
Lock Down
Sector Lock Register
bit
The Lock Registers can be read and written using the Read Lock Register (RDLR) and
Write to Lock Register (WRLR) instructions.
In each Lock Register two bits control the protection of each sector: the Write Lock bit and
the Lock Down bit.
The definition of the Lock Register bits is given in Table 9: Lock Register out.
SPM2
The second software protected mode (SPM2) uses the Block Protect bits (BP2, BP1, BP0)
and the Top/Bottom bit (TB bit) to allow part of the memory to be configured as read-only.
See
Software protection truth table (Sectors 0 to 63, 64 Kbyte granularity)
As a second level of protection, the Write Protect signal (applied on the W/VPP pin) can
freeze the Status Register in a read-only mode. In this mode, the Block Protect bits (BP2,
BP1, BP0) and the Status Register Write Disable bit (SRWD) are protected.
0
1
0
1
Write Lock
Section 16: Ordering
bit
Write Lock bit: The Write Lock bit determines whether the contents of the sector can be
modified (using the Write, Program, or Erase instructions). When the Write Lock bit is
set to '1', the sector is write protected - any operations that attempt to change the data
in the sector will fail. When the Write Lock bit is reset to '0', the sector is not write
protected by the Lock Register, and may be modified.
Lock Down bit: The Lock Down bit provides a mechanism for protecting software data
from simple hacking and malicious attack. When the Lock Down bit is set to '1', further
modification to the Write Lock and Lock Down bits cannot be performed. A powerup is
required before changes to these bits can be made. When the Lock Down bit is reset to
'0', the Write Lock and Lock Down bits can be changed.
Sector unprotected from Program/Erase/Write operations, protection status reversible.
Sector protected from Program/Erase/Write operations, protection status reversible.
Sector unprotected from Program/Erase/Write operations.
Sector protection status cannot be changed except by a power-up.
Sector protected from Program/Erase/Write operations.
Sector protection status cannot be changed except by a power-up.
information.
Protection Status
47/160