rt9645 Richtek Technology Corporation, rt9645 Datasheet - Page 8

no-image

rt9645

Manufacturer Part Number
rt9645
Description
Channels Acpi Regulator
Manufacturer
Richtek Technology Corporation
Datasheet
RT9645
Note 1. Stresses listed as the above "Absolute Maximum Ratings" may cause permanent damage to the device. These are for
Note 2. Devices are ESD sensitive. Handling precaution is highly recommended.
Note 3. The device is not guaranteed to function outside its operating conditions.
Note 4. θ
www.richtek.com
8
stress ratings. Functional operation of the device at these or any other conditions beyond those indicated in the
operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended
periods may remain possibility to affect device reliability.
JEDEC 51-3 thermal measurement standard. The case point of θ
JA
is measured in the natural convection at T
Preliminary
A
= 25°C on a low effective thermal conductivity test board of
JC
is on the expose pad for the QFN package.
DS9645-00 August 2007