mpu-800 MicroPower Direct, LLC, mpu-800 Datasheet - Page 2

no-image

mpu-800

Manufacturer Part Number
mpu-800
Description
Single Output 800w Power Factor Corrected Ac/dc Power Supplies
Manufacturer
MicroPower Direct, LLC
Datasheet
Model Selection Guide
Mechanical Dimensions
U-Chassis Cover
MPU-800S-12
MPU-800S-15
MPU-800S-24
MPU-800S-36
MPU-800S-40
MPU-800S-48
Model Number
Number
Model
YZ
YZ
YZ
YZ
YZ
YZ
Output Voltage
PreSet
12 VDC 12.0 - 14.0
15 VDC 15.0 - 19.0
24 VDC 20.0 - 26.0
36 VDC 27.0 - 36.0
40 VDC 37.0 - 47.0
48 VDC 48.0 - 60.0
292 Page Street Ste D Stoughton, MA 02072
MicroPower Direct
We Power Your Success - For Less!
(C Suffi x)
Range
(VDC)
With 30 CFM
Current
Output
(Max A)
62.50
50.00
40.00
29.63
21.62
16.67
Output
Power
Max.
750
750
800
800
800
800
(W)
& Noise
Ripple
(% p-p)
±1%
±1%
±1%
±1%
±1%
±1%
TEL: (781) 344-8226
Effi ciency
www.micropowerdirect.com
80%
80%
83%
83%
83%
83%
(%)
Notes:
1. Output regulation includes line & load.
2. Ripple & noise is measured from 10 Hz to 20 MHz. Connection to the unit
3. A 1% minimum load is required to maintain regulation & ripple specifi ca-
4. Transient recovery is measured to within a 1% error band for a load step
5. Isolation specifi cations are production HI-Pot tested for 3 seconds.
6. The full output range (see table) is covered in the safety agency certifi cation.
7. Output power is given for the factory preset voltage. With the exception
8. Each unit includes an input fuse (250V/12A). Since this fuse is not fi eld
FAX: (781) 344-8481
is made with a 0.1 µF ceramic capacitor & a 22 µF electrolytic capacitor
connected in parallel.
tions.
change of 50% to 100%.
Standard models are factory set to the Preset voltage, but may be set to
other levels within the range without affecting the agency certifi cation. For
more information, contact the factory.
of the “12” & “15” models, the maximum continuous output power level
is 800W with 25 CFM airfl ow. All models provide a peak power level of
900W for a maximum duration of 500 µS. For more information, contact
the factory.
replaceable, it is recommended that an external fuse of the same size be
used on the input of the power supply for protection.
Notes:
All dimensions are typical in inches (mm)
Tolerance x.xx =
Connections
Input Connector (CN1):
Output Connector (CN2):
Logic Signal Connector (CN3):
Fan Driver Connector (CN4):
Pin
Mating Part No:
JST XHP-7 or equivalent
(CHYAO SHIUNN JS-2001-07)
Mating Part No:
JST XHP-2 or equivalent
(CHYAO SHIUNN JS-2001-2)
Terminal Block:
Howder HD-121-3P: M3.5 Screws
3 pins, 9.5 mm Centers
Molex Mating Part No:
Molex 09-91-7000 or equivalent
(two pins removed)
Terminal Block:
Howder HD-121-8P: M3.5 Screws
8 pins, 9.5 mm Centers
Molex Mating Part No:
Molex 09-91-2000 or equivalent
1
2
3
E-Mail: sales@micropowerdirect.com
1-4
5-8
Pin
Pin
Pin
±
1
2
3
4
5
6
7
1
2
0.02 (
Howder
Field Ground
AC-Neutral
Function
Function
±
AC-Line
+V
-V
+ Remote Sense
Current Monitor
- Remote Sense
Remote On/Off
0.50)
Current Share
Power Good
OUT
OUT
Function
Function
Common
Minus
Plus
10-20
1-10
Pin
Molex
Function
+V
-V
OUT
OUT

Related parts for mpu-800