mpu-120s MicroPower Direct, LLC, mpu-120s Datasheet

no-image

mpu-120s

Manufacturer Part Number
mpu-120s
Description
120w U-channel, Power Factor Corrected, Ac/dc Power Supplies
Manufacturer
MicroPower Direct, LLC
Datasheet
MPU-120S
Key Features:
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
120W U-Channel,
Power Factor Corrected,
AC/DC Power Supplies
120W Output Power
180W Power W/18 CFM
Universal 90-264 AC Input
Active PFC = >0.99
EN 60950 Approved
Low Leakage Current
Five Single Output Models
Meets EN 55022 B
>120 kHour MTBF
Only 5.0” x 3.2” x 1.5”
Electrical Specifi cations
Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.
Parameter
Output Voltage/Current
Output Voltage Tolerance
Minimum Output Load
Line Regulation
Load Regulation
Ripple & Noise (20 MHz), See Note 3
Hold-Up Time
Temperature Coeffi cient
Short Circuit Protection
Over Voltage Protection
Overload Protection
Input
Parameter
Input Voltage Range
Input Frequency
Input Filter
Input Current
Inrush Current
Safety Ground Leakage Current
Power Factor Correction, See Note 1
Output
General
Parameter
Isolation Voltage
Isolation resistance
Isolation Capacitance
EMI/RFI
EMC Compliance
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Size
Weight
Reliability Specifi cations
Parameter
MTBF
Safety Standards
Safety Approvals
Vibration
www.micropowerdirect.com
Series
Electrical Fast Transients/Bursts On Mains
MIL HDBK 217F, 25°C, Gnd Benign
10~500 Hz, 5G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis
Electrostatic Discharge (ESD)
Conditions
Conditions
Conditions
Conditions
Conditions
RF Field Susceptibility
5, 12, 15 VDC Output
RH, Non-condensing
Cold Start, 115 VAC
Cold Start, 230 VAC
Free Air Convection (See Derating Curve)
Iout = 5% to 100%
Meets EN 55022 Class B; FCC Class B
Output to Ground
Vin = Min to Max
Input to Ground
Input to Output
48 VDC Output
>125% Vout (Autorecovery)
See Model Selection Guide
See Model Selection Guide
Continuous (Autorecovery)
UL, cUL; File No. E245422
Conducted
With Cover
See Note 2
See Note 4
U-Channel
5.0 x 3.24 x 1.5 Inches (127.0 x 82.2 x 38.1 mm)
UL 60950, EN 60950
Universal
500 VDC
115 VAC
230 VAC
115 VAC
230 VAC
115 VAC
Ambient
Surge
Fixed
4,000
2,000
Min.
Min.
Min.
Min.
Min.
0.99
0.95
120
130
500
120
-25
-40
0.0
90
47
15
EN 55022; EN 61000-3-2, -3
±0.02
4,700
Typ.
0.47
0.94
Typ.
±2.0
±1.0
±1.0
Typ.
Typ.
Typ.
100
100
+25
EN 61000-4-2, -6, -8, -11
13.47 Oz (0.382 kg)
14.10 Oz (0.400 kg)
Max.
Max.
Max.
Max.
Max.
30.0
60.0
264
370
100
150
+70
+85
63
50
95
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
mV P - P
kHours
mSec
Units
W/VA
Units
%/°C
Units
Units
Units
VDC
A Pk
VAC
VAC
kHz
M
mA
Hz
pF
°C
°C
%
%
%
%
%
%

Related parts for mpu-120s

mpu-120s Summary of contents

Page 1

... MPU-120S 120W U-Channel, Power Factor Corrected, AC/DC Power Supplies Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. Input Key Features: Parameter • 120W Output Power Input Voltage Range • ...

Page 2

... MPU-120S-05 2.0 1.0 YZ MPU-120S-12 2.0 1.0 12.0 YZ MPU-120S-15 2.0 1.0 15.0 YZ MPU-120S-24 2.0 1.0 24.0 YZ MPU-120S-48 2.0 1.0 48.0 YZ For Open Frame models, see MPO-120S Datasheet Model Number Connector Options Derating Curve MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 www.micropowerdirect.com Output Current Ouput Power (A) (W Max) Free Free 18 CFM ...

Related keywords