h7cx-a114-n Omron Corporation, h7cx-a114-n Datasheet - Page 43

no-image

h7cx-a114-n

Manufacturer Part Number
h7cx-a114-n
Description
Multifunction Counter/tachometer
Manufacturer
Omron Corporation
Datasheet
Operating Procedures
Parameters must be set using both the DIP switch and the operation keys on the front panel.
Refer to the following for the detailed procedure.
*1. The setting of Pin 1 is disabled (OFF) for the H7CX-R11W@.
*2. For the H7CX-R11W@.
The settings made using the DIP switch can be checked in the
DIP switch monitor mode.
Note: The characters displayed in reverse video are the default settings.
Set the basic parameters.
*3. For the H7CX-R11W@, the counting speed will be 5 kHz even if 10 kHz
Note: The characters displayed in reverse video are the default settings.
Step1
1
2
3
4
5
6
7
8
is selected.
3
4
Output mode
Output mode
Input mode
Counting speed/
Minimum input signal width
Output mode
Average processing
NPN/PNP input mode
---
*1
Item
Item
*2
Refer to the table on the right.
Refer to the table on the right.
Refer to the table on the right.
Refer to the table on the right.
Refer to the table on the right.
NPN
OFF
---
OFF
PNP
ON
---
ON
(Factory setting)
OFF
ON
1 2 3 4 5 6 7 8
Pin 1
Pin 6
Pin 5
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
Pin 3
Pin 4
OFF
OFF
ON
ON
Pin 2
Pin 4
Pin 6
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
Output mode
Output mode
Upper limit
Upper limit
Lower limit
Lower limit
AMD compatible
AMD compatible
OFF (no average processing)
Input mode
Tachometer
Tachometer
Average processing
Upper and lower limit
Output mode
Upper limit
Lower limit
2 times
4 times
8 times
Area
minimum input signal width
Counting speed/
H7CX-R@-N
10 kHz
10 ms
30 Hz
1 ms
*3
43

Related parts for h7cx-a114-n