jws120p DENSEI-LAMBDA, jws120p Datasheet

no-image

jws120p

Manufacturer Part Number
jws120p
Description
Peak Current/single Output 70 ~ 480w
Manufacturer
DENSEI-LAMBDA
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
jws120p-24
Manufacturer:
MITSUBISHI
Quantity:
200
JWS-P
(*1) Operating time at peak output is less than 10 seconds. (Duty
JWS70P
JWS120P
JWS240P
JWS480P
1. Input voltage range
2. Power Factor
3. Cooling
4. Operating
5. Withstand Voltage
6. Conducted
7. Radiated emission
8. PFHC
9. Safety standard
10. Functions
JWS70P
Specifications
Line-up
Outline drawing
JWS70P
Temperature
emission noise
noise
(Low Voltage Directive)
Recommended Noise Filter
Recommended Power Supply Fixture
MAW-1202-22
Model
JWS120P-24
JWS120P-48
JWS240P-24
JWS240P-36
JWS240P-48
JWS480P-24
JWS480P-48
JWS70P-24
JWS70P-48
JWS120P
-SERIES
Note: JWS150P 24V output with cover model - UL508 approval is expencted to be confirmed in August 2002
85 ~ 265VAC ( 47 ~ 63Hz) Universal input
0.99 (typ) at 100VAC Average load, 0.92 (typ) at 200VAC Average load
JWS70P, JWS120P: Convection cooling, JWS240P, JWS480P: Forced air by built-in blower
–10 ~ +60°C (–10 ~ +50°C: 100%, +60°C: 60%)
Input to output: 3kVAC (20mA), Input to FG: 2kVAC (20mA), Output to FG: 500VAC (100mA) for 1 min.
Built to meet EN55011-A, EN55022-A, FCC class A, VCC I class A
Built to meet EN55011-A, EN55022-A, FCC class A, VCC I class A
Built to meet EN61000-3-2
Approved by UL1950
OVP, OCP, Thermal protection, JWS240P, JWS480P: Remote ON/OFF control
P134
( 0
Voltage
Output
24V
48V
24V
48V
24V
36V
48V
24V
48V
JWS240P
< =
0.5)
( 0
Average Output
, CSA950
Current
P198
10.0A
6.65A
20.0A
10.0A
Peak current / Single output 70 ~ 480W
3.0A
1.5A
5.0A
2.5A
5.0A
JWS480P
*24V output with cover
, EN60950
3 year warranty
Average Output
239.4W
Power
120W
120W
240W
240W
480W
480W
72W
72W
, VDE0160
Applicable to peak output current, compact package
Universal Input (85 ~ 265VAC)
Power Factor & Harmonic Correction (Conform to EN61000-3-2)
EMI (Built to meet EN55011-A, EN55022-A, VCCI-A, FCC-A)
Remote ON/OFF control (JWS240P & JWS480P)
Peak output
Current (*1)
Model name
JWS120P - 24
Features
marking (Low Voltage Directive)
10.0A
20.0A
13.3A
10.0A
40.0A
20.0A
6.0A
3.0A
5.0A
and UL508
Series name
Peak output
Power (*1)
478.8W
144W
144W
240W
240W
480W
480W
960W
960W
Average output power
Nominal output voltage
(optional, Note)
: Safety standard approved
UL
CSA
(Unit: mm)
29
EN

Related parts for jws120p

jws120p Summary of contents

Page 1

... Input voltage range 85 ~ 265VAC ( 47 ~ 63Hz) Universal input 2. Power Factor 0.99 (typ) at 100VAC Average load, 0.92 (typ) at 200VAC Average load 3. Cooling JWS70P, JWS120P: Convection cooling, JWS240P, JWS480P: Forced air by built-in blower 4. Operating –10 ~ +60°C (–10 ~ +50°C: 100%, +60°C: 60%) Temperature 5. Withstand Voltage Input to output: 3kVAC (20mA), Input to FG: 2kVAC (20mA), Output to FG: 500VAC (100mA) for 1 min. ...

Page 2

... JWS-P -SERIES Outline drawing JWS120P Recommended Noise Filter Recommended Power Supply MAW-1202-22 Fixture ( 0 P134 JWS240P JWS480P P198 A A NOTE A: M4 tapped holes (20) for customer chassis mounting. [Screws must not protrude into power supply by more than 6m/m NOTE A: M4 tapped holes (16) for customer chassis mounting. ...