m-fiam7hs3 Vicor Corporation, m-fiam7hs3 Datasheet

no-image

m-fiam7hs3

Manufacturer Part Number
m-fiam7hs3
Description
Military Cots 28 Vin Filter Input Attenuator Module
Manufacturer
Vicor Corporation
Datasheet
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
• EMI filtering-MIL-STD-461E
• Transient protection-MIL-STD-1275A/B/D,
• Environments-MIL-STD-810, MIL-STD- 202
• Environmental stress screening
• Low profile mounting options
• Output current up to 10 Amps
• Mini sized package
• Inrush current limiting
• Reverse polarity protection
The M-FIAM7 is a DC front-end module that
provides EMI filtering and transient
protection. The M-FIAM7 enables designers
using Vicor’s 28 V DC-DC V•I Chip modules
to meet conducted emission/ conducted
susceptibility per MIL-STD-461E; and input
transients per MIL-STD-1275A/B/D,
MIL-STD-704A-F and DO-160E. The
M-FIAM7 accepts an input voltage of
14 – 50 Vdc and delivers output current
up to 10 A.
M-FIAM7 is housed in an industry
standard "half brick" module measuring
2.28" x 2.2" x 0.5" and depending upon
model selected, may be mounted onboard
or inboard for height critical applications.
• 28 V Input DC-DC V•I Chip modules.
Note: This product is not compatible with
Maxi, Mini, Micro DC-DC converters.
MIL-STD-704A-F and DO-160E
Set your site on VICOR at vicorpower.com
M-FIAM7
*Compatible with SurfMate and InMate socketing system.
Parameter
+In to –In
Mounting torque
Pin soldering temperature
M-FIAM7
Parameter
Baseplate to sink
Baseplate to ambient
Temperature
25°C
50°C
65°C
flat, greased surface
with thermal pad (P/N 20264)
Free convection
1000 LFM
Product
57,9 x 55,9 x 12,7 mm
Shown actual size:
2.28 x 2.2 x 0.5 in
Grade
Product Grade Temperatures (°C)
M =
H =
Environment
Ground Benign: G.B.
Naval Sheltered: N.S.
Airborne Inhabited Cargo: A.I.C.
–55 to +100
–40 to +100
Operating
MFIAM7
M
Min
– 65 to +125
–55 to +125
500 (260)
750 (390)
5 (0.57)
Storage
Rating
100
50
0.16
Typ
0.1
7.9
2.2
1 = Short Pin
2 = Long Pin
S = Short ModuMate*
N = Long ModuMate*
Rev. 1.6
°F(°C)
°F(°C)
MTBF
in-lbs
3,540
Unit
Vdc
Vdc
637
499
Max
Pin Style
2
Notes
Continuous
See Fig.1
6 each, #4-40 or M3
<5 sec; wave solder
<7 sec; hand solder
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Unit
1,000 Hrs
1,000 Hrs
1,000 Hrs
1 = Slotted
2 = Threaded
3 = Thru hole
Baseplate
Page 1 of 6
1

Related parts for m-fiam7hs3

m-fiam7hs3 Summary of contents

Page 1

... V Input DC-DC V•I Chip modules. Note: This product is not compatible with Maxi, Mini, Micro DC-DC converters. Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Set your site on VICOR at vicorpower ...

Page 2

... Years MFIAM7 Notes Continuous 50 ms per MIL-STD-1275A/B/D, continuous operation 70 µs per MIL-STD-1275B, continuous operation 20 ms per MIL-STD-704A, continuous operation 100 ms per DO-160E, Section 16, Power Input, Category Z Notes @10 A, 100°C baseplate See illustration C1 on page Notes Referenced to – Vout 100 kΩ internal pull-up resistor ...

Page 3

... MIL-STD-810F, Method 514.5, Procedure I, Category 14, Sine and Random vibration per Table 514.5C for Helicopter AH-6J Main Rotor with overall level of 5.6 G rms for 4 hours per axis. MIL-STD-810F, Method 514.5C, General Minimum Integrity Curve per Figure 514.5C-17 with overall level of 7.7 G rms for 1 hour per axis. ...

Page 4

... Vin (V) Figure 1 Figure 3 –IN – EMI MOV P/N GND 19180-510 NC + +IN Figure 5 Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Set your site on VICOR at vicorpower.com 105 110 120 Figure 2 Figure – OFF PRM- +In MFIAM7 NC + – ...

Page 5

... DIA,(7X) 10,16 2,03 0.700 17,78 1.000 25,40 1.400 35,56 * Slotted baseplate only ** Threaded & through hole (style 2 & 3) baseplates *** Reserved for Vicor accessories. Not for mounting C L Pin center line INBOARD ONBOARD SOLDER SOLDER MOUNT MOUNT SHORT PIN STYLE LONG PIN STYLE 0.094 ±0.003 0.094 ± ...

Page 6

... Vicor does not assume any liability arising out of the application or use of any product or circuit; neither does it convey any license under its patent rights nor the rights of others. Vicor general policy does not recommend the use of its components in life support applications wherein a failure or malfunction may directly threaten life or injury. Per Vicor Terms and Conditions of Sale, the user of Vicor components in life support applications assumes all risks of such use and indemnifies Vicor against all damages ...