FEATURES
SIMPLIFIED SCHEMATIC DIAGRAM
Scientific-grade accuracy, ±2 counts
Low power, typically 12.5mW
Miniature size:
2.17" x 0.92" x 0.43" (55mm x 23mm x 11mm)
Large (0.4”/10.2mm), enhanced-contrast, LCD display
Backlit displays optional
Epoxy-encapsulated, 12-pin DIP
Panel or pc-board mountable
3 differential, dual, input voltage ranges
Single +5V supply or 9V battery
User-selectable decimal point placement
Low-battery "BAT" annunciator
0 to +50°C temperature range
Low Cost
www.murata-ps.com/rohs
For full details go to
 
+5V SUPPLY/
5V RETURN/
+BATTERY
–BATTERY
SELECT
R1 = 100k on ±200mV/±2V (-0/1) models and 909k on all other models.
R2 is not used on ±200mV/±2V (-0/1) models.
R2 = 101k on ±2V/±20V (-1/2) models and 9.2k on ±20V/±200V (-2/3) models.
RANGE
DP 3
DP 2
DP 1
1
2
3
4
5
6
www.murata-ps.com
0 Vdc
CONVERTER
DC/DC
component-like convenience and outstanding reliability, DMS-40LCD Series 4½ Digit DPM’s
provide the ultimate combination of price, precision and convenience. These miniature
(2.17” x 0.92” x 0.43”) digital voltmeters combine an advanced, autozeroing A/D converter,
a precision reference circuit and a large (0.4”/10.2mm high), easy-to-read LCD display in a
single, fully encapsulated, 12-pin DIP package. All models incorporate a built-in bezel and
are easily mounted in either panels or pc boards.
(±200mV/±2V, ±2V/±20V or ±20V/±200V) and is available with a backlit or non-backlit
display. Input impedance is a minimum 800kΩ, and CMRR is typically 86dB (dc to 60Hz).
CMV is ±2V, and all models are overvoltage protected to ±250V (on their non-inverting
inputs).
ing 3.5mA max.) or a single 9V supply/battery (drawing 2.5mA max.). All models feature
autopolarity changeover and overrange indication. A display HOLD function is standard on
all non-backlit models.
ibrated A/D converters, DMS-40LCD meters are able to withstand the harshest environ-
ments and never require adjustment or calibration. Plug-in convenience, long-term stability
and wide operating temperature range (0 to +50°C) make DMS-40LCD meters the right
solution for any high-accuracy DPM requirement.
BAT
BAT
J1
+5V
Offering a unique combination of low cost, scientific-grade accuracy (±2 counts),
Each DMS-40LCD meter has a dual-range, differential, input configuration
All DMS-40LCD meters are fully functional and operate from a single +5V supply (draw-
Thanks to their rugged epoxy-based encapsulation and their advanced, factory-cal-
DATA
CONVERTER
–5V
A/D
4½ Digit, LCD Display Digital Panel Voltmeters
V+
V–
Technical enquiries email: sales@murata-ps.com, tel:
Hold function is not available on backlit models.
DC/DC converter is not used on 9V-powered models,
J1 is connected.
DMS-40LCD Series
1.23V
+5V
REF.
0.01μF
+2.2V
MPM_DMS40LCD.C02 Page 1 of 6
R2
R1
12
11
10
9
8
7
HOLD/
BACKLIGHT
DP 4
REFERENCE
IN/OUT
ANALOG
COMMON
(–) INPUT LO
(+) INPUT HI
+1 508 339 3000

Related parts for DSD-40LCD-0/1-5-C

DSD-40LCD-0/1-5-C Summary of contents

Page 1

FEATURES Scientific-grade accuracy, ±2 counts Low power, typically 12.5mW Miniature size: 2.17" x 0.92" x 0.43" (55mm x 23mm x 11mm) Large (0.4”/10.2mm), enhanced-contrast, LCD display Backlit displays optional Epoxy-encapsulated, 12-pin DIP Panel or pc-board mountable 3 differential, dual, input ...

Page 2

Performance/Functional Specifications Typical +25°C and supply voltage = +5V (using the single-ended input circuit +9V (using the differential input circuit), unless otherwise noted. Analog Inputs Min. Full Scale Input Range: DMS-40LCD-0/1 – DMS-40LCD-1/2 – DMS-40LCD-2/3 ...

Page 3

Low Battery Annunciator: The “BAT” annunciator in the upper left-hand corner of the display turns on when the supply voltage for 5V-powered models falls below approximately +3.75V or when the supply voltage for 9V-powered models falls below approximately 7.2V. ...

Page 4

APPLICATIONS 2. Differential Input Configurations: Differential measurements can be made with either 5V-powered or 9V-powered meters. Figure 3, though not a practical real-world application, uses a voltage divider to demon- strate the concept of a differential input signal. Be careful ...

Page 5

APPLICATIONS 5. Process Control (4-to-20mA) Measurements: In many common process-control applications, a 4-to-20mA current loop is used to transmit information. Because DMS-40LCD meters have such high input impedance, a simple shunt resistor across the meter’s input can be used to ...

Page 6

MECHANICAL SPECIFICATIONS MECHANICAL DIMENSIONS: Inches (mm) TOLERANCES DEC ±0.02 (±0.51 DEC ±0.010 (±0.254) LEAD DIMENSIONS: 0.025 (0.635) x 0.025 (0.635) NOMINAL RECOMMENDED PC BOARD FINISHED HOLE DIAMETER: 0.042 ±0.003 (1.067 ±0.076) PIN 1 BEZEL INSTALLATION AND ...