MIC2076 MICREL [Micrel Semiconductor], MIC2076 Datasheet - Page 12

no-image

MIC2076

Manufacturer Part Number
MIC2076
Description
Dual-Channel Power Distribution Switch
Manufacturer
MICREL [Micrel Semiconductor]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MIC2076-1BM
Manufacturer:
MICREL
Quantity:
522
Part Number:
MIC2076-1YM
Manufacturer:
MICREL
Quantity:
3 500
Part Number:
MIC2076-1YM
Manufacturer:
MICREL/麦瑞
Quantity:
20 000
Part Number:
MIC2076-1YM TR
Manufacturer:
MICREL
Quantity:
2 500
Part Number:
MIC2076-1YM-TR
0
Part Number:
MIC2076-2BM
Manufacturer:
NS
Quantity:
10 770
Part Number:
MIC2076-2YM
Manufacturer:
MICREL
Quantity:
142
Part Number:
MIC2076-2YM
Manufacturer:
MICREL/麦瑞
Quantity:
20 000
Company:
Part Number:
MIC2076-2YM
Quantity:
270
Part Number:
MIC2076A-2YM
Manufacturer:
MICREL/麦瑞
Quantity:
20 000
where:
Current Sensing and Limiting
The current-limit threshold is preset internally. The
preset level prevents damage to the device and external
load but still allows a minimum current of 500mA to be
delivered to the load.
The current-limit circuit senses a portion of the output
MOSFET switch current. The current-sense resistor
shown in the block diagram is virtual and has no voltage
drop. The reaction to an overcurrent condition varies
with three scenarios:
Switch Enabled into Short-Circuit
If a switch is enabled into a heavy load or short-circuit,
the switch immediately enters into a constant-current
mode, reducing the output voltage. The FLG signal is
asserted indicating an overcurrent condition.
Short-Circuit Applied to Enabled Output
When a heavy load or short-circuit is applied to an
enabled switch, a large transient current may flow until
the current-limit circuitry responds. Once this occurs, the
device limits current to less than the short-circuit current
limit specification.
Micrel, Inc.
June 2010
T
T
T
θ
JA
J
J
A
= P
= junction temperature
= ambient temperature
= is the thermal resistance of the package
D
× θ
JA
+ T
A
I
V
I
I
LOAD
V
V
I
LIMIT
LOAD
V
I
V
LIMIT
I
OUT
OUT
V
OUT
OUT
FLG
FLG
EN
EN
Figure 1. MIC2076-2 Fault Timing: Output Reset by Removing Load
3ms typ.
3ms typ.
delay
delay
Figure 2. MIC2026-2 Fault Timing
Short-Circuit Fault
Short-Circuit Faul t
Shutdown
Reached
Thermal
Shutdown
Reached
Thermal
12
Load/Fault
Removed
Current-Limit Response—Ramped Load
The MIC2026/76 current-limit profile exhibits a small
foldback effect of about 200mA. Once this current-limit
threshold is exceeded the device switches into a
constant current mode. It is important to note that the
device will supply current up to the current-limit
threshold.
Fault Flag
The FLG signal is an N-channel open-drain MOSFET
output. FLG is asserted (active-low) when either an
overcurrent or thermal shutdown condition occurs. In the
case of an overcurrent condition, FLG will be asserted
only after the flag response delay time, t
This ensures that FLG is asserted only upon valid
overcurrent conditions and that erroneous error reporting
is eliminated. For example, false overcurrent conditions
can occur during hot plug events when a highly
capacitive load is connected and causes a high transient
inrush current that exceeds the current-limit threshold for
up to 1ms. The FLG response delay time t
3ms.
Undervoltage Lockout
Undervoltage lockout (UVLO) prevents the output
MOSFET
approximately 2.5V. Undervoltage detection functions
only when the switch is enabled.
Load and Fault Removed
(Output Reset)
from
turning
on
until
M9999-060410-B
MIC2026/2076
D
V
, has elapsed.
IN
D
is typically
exceeds

Related parts for MIC2076