2.4 Power Down mode
2.5 Recommended start-up sequence
VTI Technologies Oy
www.vti.fi
For low power applications it is possible to set the accelerometer into power down mode. During
the power down mode the power consumption is minimized inside the device. This is achieved by
stopping the internal clocks and resetting the control registers of the device. Please refer to the
individual device data sheets for detail power consumption figures.
For correct device operation there are no specific configuration needed for the device before
starting of measuring the acceleration. However if the device detail features are being used the
following operations could be made after the powering on the device.
Table 2: SCA8X0 start up sequence
Item
1
2
3
4
5
6
Procedure
Set Vdd=3.0...3.6V
Wait 95ms
Read CTRL-register
Read STATUS-register
Write CTRL=0000 0000
Read X_MSB, X_LSB –
registers
Doc. Nr. 82 694 00 C
Functions
Set the
power on to
release part
from reset
and to start
the operation
During the
first 95ms the
part is
performing
the memory
read and self-
diagnostics.
Possible
signal path
self-
diagnostic
test is carried
out.
Settling of
signal path
Check the
self-test pass
status
Check the
memory
checksum
pass status
After device
power on set
PORST=0 to
be able to
detect any
future
occurring
power
failures
Start reading
the
acceleration
data
Check
-
-
CTRL.ST=0
SPI fixed bits
dPAR, data parity
STATUS.CSMERR=0
SPI fixed bits
SPI FRME=0
dPAR, data parity
SPI fixed bits
SPI FRME=0
SPI fixed bits
SPI FRME=0
SPI PORST=0
dPAR, data parity
SCA8X0/21X0/3100 Series
9/35