USB-6525 NI [National Instruments Corporation], USB-6525 Datasheet

no-image

USB-6525

Manufacturer Part Number
USB-6525
Description
Small, portable digital I/O device / Eight channel-to-channel optically isolated inputs
Manufacturer
NI [National Instruments Corporation]
Datasheet
Industrial Digital I/O Device for USB –
60 V, Channel-to-Channel Isolated
NI USB-6525
• Small, portable digital I/O device
• Eight channel-to-channel optically
• Eight channel-to-channel optically
• 500 mA maximum switching current
• One 32-bit event counter
• Full-speed USB (12 Mb/s) bus interface
• Built-in, removable connectors for
• USB cable strain relief
Table 1. NI USB-6525 Specifications Overview
Overview and Applications
The National Instruments USB-6525 is a full-speed USB device with
eight normally open, channel-to-channel isolated, solid-state relay
outputs and eight ±60 VDC channel-to-channel isolated digital inputs.
The NI USB-6525 offers features for industrial control and manufacturing
test applications, such as factory automation, embedded machine
control, and production line verification. The solid-state relay outputs
have a 60 VDC/30 V
switching current, making them ideal for controlling pumps, valves,
motors, and other industrial actuators. The eight isolated digital input
channels break ground loops and offer protection from noise and spikes
on external signals. You can also use one of the digital input channels as
a 5 kHz, 32-bit event counter for counting digital pulses.
Hardware
The USB-6525 has eight channel-to-channel optically isolated inputs,
P1.<0..7>, and eight channel-to-channel optically isolated, solid-state
relay outputs, P0.<0..7>. The isolated inputs consist of an optocoupler, a
depletion-mode MOSFET-based current-limiting circuit, and a Schottky
diode. Each channel has its own positive and negative terminals capable
of detecting a wide range of DC signals, from 5 V TTL logic levels to DC
power supply levels up to 60 V.
NI USB-6525
isolated inputs (±60 VDC)
isolated, solid-state relay outputs
(60 VDC/30 V
per channel
easy connectivity
Product
Digital Inputs
rms
max)
8
rms
switching voltage and 500 mA/ch maximum
Low Threshold
1 VDC
High Threshold
Operating Systems
• Windows Vista/XP/2000
Recommended Software
• LabVIEW
• LabWindows
• Measurement Studio
• LabVIEW SignalExpress
Other Compatible Software
• Visual Studio .NET
• C, C++
• Visual Basic
Measurement Services
Software (included)
• NI-DAQmx driver software
• Measurement & Automation Explorer
• LabVIEW SignalExpress LE
configuration utility
data-logging software
3.2 VDC
Input Current
/CVI
3 mA/ch
SSR Outputs
counter. In this mode, the device counts low to high transitions on P1.7.
You can arm and disarm the counter as well as read or reset the count
through software.
DC power source. The default power-on state of the solid-state relays is
open. The relays also remain open when the computer and the USB-6525
device are powered off.
Table 2. NI USB-6525 Pinout
8
PFI 0 (an alias to P1.7) can also function as the source for a 32-bit
You can connect loads to the solid-state relay outputs with an AC or
Module
Switching Current
Terminal
500 mA
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
9
Signal
P0.0A
P0.1A
P0.2A
P0.3A
P0.4A
P0.5A
P0.6A
P0.7A
Max Signal Range
P0.0B
P0.1B
P0.2B
P0.3B
P0.4B
P0.5B
P0.6B
P0.7B
±60 VDC
Module
Isolation
Ch-to-Ch
Terminal
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
32-Bit Counters
P1.7 + /PFI 0 +
P1.7 - /PFI 0 -
Signal
P1.0 +
P1.0 -
P1.1 +
P1.1 -
P1.2 +
P1.2 -
P1.3 +
P1.3 -
P1.4 +
P1.4 -
P1.5 +
P1.5 -
P1.6 +
P1.6 -
1

Related parts for USB-6525

Related keywords