NQ40T40EGC08NKC-G SYNQOR [SynQor Worldwide Headquarters], NQ40T40EGC08NKC-G Datasheet
NQ40T40EGC08NKC-G
Related parts for NQ40T40EGC08NKC-G
NQ40T40EGC08NKC-G Summary of contents
Page 1
Continuous Input Outputs The NiQor eighth-brick dc-dc converter is a non-isolated ® buck-boost regulator, which employs synchronous rectification to achieve extremely high conversion efficiency. The High Input Voltage NiQor Brick family of ...
Page 2
Technical Specification MECHANICAL DIAGRAM 0.99 (25) 0.600 (15.24) 0.450 (11.43) 0.300 (7.62) 0.150 (3.81) 2.39 (60.6) 2.00 (50.8) 0.18 (4.6) 0.19 (4.9) 0.300 (7.62) 0.600 (15.24) NOTES 1) Pins 1-3, 5-7 are 0.040" (1.02 mm) diameter. with 0.080" (2.03mm) diameter ...
Page 3
Technical Specification NQ40x40EGC08 ELECTRICAL CHARACTERISTICS °C, airflow rate = 300 LFM, Vin = unless otherwise noted; full operating temperature range is -40 °C to +105 °C ambient temperature with appropriate power derating. Specifications subject ...
Page 4
Technical Specification NQ40x40EGC08 ELECTRICAL CHARACTERISTICS (Continued °C, airflow rate = 300 LFM, Vin = unless otherwise noted; full operating temperature range is -40 °C to +105 °C ambient temperature with appropriate power derating. Specifications ...
Page 5
Technical Specification 100 Load Current (A) Figure 1: Efficiency at nominal output voltage vs. load current for nominal input voltage °C 7.5 6.0 4.5 ...
Page 6
Technical Specification Figure 7: Output voltage response for 24 V input output to step-change in load current (50-75-50% of Iout max; di/dt=0.1A/µs). Load cap: 100 µF, 100 mW ESR tant, Ch 1-3: Vout (2 ...
Page 7
Technical Specification BASIC OPERATION AND FEATURES These converters use a digital controller for the buck stage and boost stage (see Figure A). It automatically changes operating mode (buck mode or boost) when the line voltage or output set point changes. ...
Page 8
Technical Specification APPLICATION CONSIDERATIONS Limited output voltage resolution: The internal voltage control feedback loop has limited resolution. Therefore, the output voltage will exhibit discrete steps as the loop responds to changes in line, load, trim, or remote sense. For instance, ...
Page 9