NQ40T40EGC08NKC-G SYNQOR [SynQor Worldwide Headquarters], NQ40T40EGC08NKC-G Datasheet - Page 4

no-image

NQ40T40EGC08NKC-G

Manufacturer Part Number
NQ40T40EGC08NKC-G
Description
Eighth-brick DC-DC Converter
Manufacturer
SYNQOR [SynQor Worldwide Headquarters]
Datasheet
Product # NQ40x40EGC08
NQ40x40EGC08 ELECTRICAL CHARACTERISTICS (Continued)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 24 V dc unless otherwise noted; full operating temperature range is -40 °C to +105 °C ambient temperature with appropriate power derating. Specifications subject
STANDARDS COMPLIANCE
Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new
QUALIFICATION TESTING
Note: Extensive characterization testing of all SynQor products and manufacturing processes is performed to ensure that we supply
DYNAMIC CHARACTERISTICS
Output Voltage during Current Transient
Settling Time
Turn on Transient
Startup delay
Rise Rate
Output Voltage Overshoot
FEATURE CHARACTERISTICS
Switching Frequency
ON/OFF Control
Negative Logic (N) ON/OFF Control
Off-State Voltage
On-State Voltage
Pull-Up Voltage
Pull-Up Resistance
Output Voltage Trim Range
Input/Output Over-Voltage Protection
Over-Temperature Shutdown
Over-Temperature Shutdown Restart Hysteresis
RELIABILITY CHARACTERISTICS
Calculated MTBF (TR-NWT-000332; Telcordia)
Calculated MTBF (MIL-HDBK-217F; MIL-217)
Field Demonstrated MTBF
STANDARDS COMPLIANCE
UL/cUL 60950-1
EN60950-1
Needle Flame Test (IEC 695-2-2)
IEC 61000-4-2
GR-1089-CORE
Telcordia (Bellcore) GR-513
QUALIFICATION TESTING
Life Test
Vibration
Mechanical Shock
Temperature Cycling
Power/Thermal Cycling
Design Marginality
Humidity
Solderability
Parameter
Parameter
Parameter
Technical Specification
For a Step Change in Output Current
releases or download from the SynQor website.
robust, reliable product. Contact the factory for official product family qualification documents.
Phone 1-888-567-9596
Pending UL Approval File # E194341
Certified by TUV
Test on entire assembly; board & plastic components UL94V-0 compliant
ESD test, 8 kV - NP, 15 kV air - NP (Normal Performance)
Section 7 - electrical safety, Section 9 - bonding/grounding
Notes & Conditions
# Units
Vout Min. Typ. Max.
15 pins
All
All
All
All
All
All
All
All
All
All
All
All
All
All
All
All
All
32
10
5
5
5
5
5
240
1.8
44
0
0
95% rated Vin and load, units at derating point, 1000 hours
10-55 Hz sweep, 0.060" total excursion, 1 min./sweep, 120 sweeps for 3 axis
100g minimum, 2 drops in x and y axis, 1 drop in z axis
-40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles
Toperating = min to max, Vin = min to max, full load, 100 cycles
Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105% load
85 °C, 85% RH, 1000 hours, continuous Vin applied except 5 min/day
MIL-STD-883, method 2003
Test Conditions
www.synqor.com
TBD
TBD
250
115
0.4
3.3
10
48
15
5
2
1
260
3.3
0.8
40
50
0
10 6 Hrs. 100% load, 200LFM, 40 °C Ta
10 6 Hrs. 100% load, 200LFM, 40 °C Ta
10 6 Hrs. See our website for details
Units Notes & Conditions
V/ms
kHz
ms
ms
°C
°C
V
V
V
V
V
V
V
Doc.# 005-NG4040W Rev. C
(0.1 A/µs); 50%-75%-50% Iout max
To within 1.5% Vout nom.
Resistive load
Measured Vout+ to common pins
Over full temp range
Average PCB Temperature
"
"
Package:
Outputs:
Current:
Input:
03/06/09
9 - 40 V
0 - 40 V
7.5 A
Eighth-brick
Page 4