SPW48S24-100R WALL [Wall Industries,Inc.], SPW48S24-100R Datasheet

no-image

SPW48S24-100R

Manufacturer Part Number
SPW48S24-100R
Description
100W DC-DC Converter 18-75 Vdc Input 24Vdc Output at 4.16A Half-Brick Package
Manufacturer
WALL [Wall Industries,Inc.]
Datasheet
Features:
• 84% Efficient at Full Load
• Fast Transient Response
• Operation to No Load
• Output Trim +/-10%
• Remote ON/OFF (Active High/Low)
• Remote Sense Compensation
• Delivers a Continuous 50W at 25°C
Description:
The SPW series is a high-density half brick converter that incorporates the desired features required in
today’s demanding applications. When performance, reliability, and low cost are needed, the SPW
series delivers.
with No Air
(888) 597-WALL
SPW48S24-100
100W DC-DC Converter
24Vdc Output at 4.16A
Half-Brick Package
18-75 Vdc Input
www.wallindustries.com
• Low Output Ripple
• Fixed Switching Frequency
• Output Over Current Protection
• Output Short Circuit Protection
• Over Temperature Protection
• 1500 V Isolation
• 100% Burn In
• Test Board Available
• UL 1950 Listed – CE Mark
TECHNICAL DATASHEET
1 of 13
Rev. A

Related parts for SPW48S24-100R

SPW48S24-100R Summary of contents

Page 1

... SPW48S24-100 Features: • 84% Efficient at Full Load • Fast Transient Response • Operation to No Load • Output Trim +/-10% • Remote ON/OFF (Active High/Low) • Remote Sense Compensation • Delivers a Continuous 50W at 25°C with No Air Description: The SPW series is a high-density half brick converter that incorporates the desired features required in today’ ...

Page 2

... Recovery to within 1% Nominal Vout From Vin (min) to Vout (nom) Full Load Resistive From Vin (min ULVO_Turn_Off Active High or Active Low (Add an ‘R’ to the end of the PN ie: SPW48S24-100R) Min High to Enable Max Low to Disable Over Operating Voltage Range V =0V, Vin=75V ...

Page 3

... WALL INDUSTRIES, INC. Figure 1: Mechanical Dimensions (888) 597-WALL TECHNICAL DATASHEET Rev A www.wallindustries.com SPW48S24-100 Page ...

Page 4

... With Active-High, if the ENABLE pin is left floating, the supply will be enabled. Active-Low means that a logic low at the ENABLE pin will turn ON the supply. With Active-Low, if the ENABLE pin is left floating, the supply will be disabled. If remote On/Off is not used on an Active-Low supply, short the Enable pin to –Vin. (888) 597-WALL TECHNICAL DATASHEET Rev A Figure 2. Remote (L/E) www.wallindustries.com SPW48S24-100 Page ...

Page 5

... R LIM  V REF  Schematic 2: Trim High MODEL LIM (Output (K (K Voltage) OHMS) OHMS) 3.3V 0.750 0.499 5.0V 2.49 10.0 12.0V 9.53 13.7 15.0V 12.4 13.7 24.0V 21.5 15.4 Table 1 : Trim Low/High Data Table. www.wallindustries.com TECHNICAL DATASHEET SPW48S24-100 REF (K (VOLTS) OHMS) 2.32 2.495 2.49 2.495 2.49 2.495 2.49 2.495 2.49 2.495 Page ...

Page 6

... Divide this power by the desired trimmed high voltage to get the maximum current at that ambient. When trimming low, the maximum current stays the same as shown in graph 2. (888) 597-WALL Rev A Graph 1: SPW48S24-100 Efficiency vs. Output Current Vin=36V Vin=48V Vin=60V Vin=75V 1 ...

Page 7

... Rev A Graph 4: SPW48S24-100 Power Dissipation vs. Input Voltage 30 Io=0A Io=1.04A 25 Io=2.08A Io=3.12A 20 Io=4.16A Graph 6: SPW48S24-100 "Remote Off" Input Current and 3 2.5 3 2.0 2 1.5 2 1.0 1 0 www.wallindustries.com TECHNICAL DATASHEET SPW48S24-100 Io=0A Io=1.04A Io=3.12A Io=4 ...

Page 8

... Photo 3: Remote Turn ON (Chan 1=Enable, Chan 2=Vout) Vin=48V, Iout = 4.16A (888) 597-WALL TECHNICAL DATASHEET Rev A Photo 2: Input Ripple Voltage(1) and Current-20mA/Div. (2). Vin=48V, Iout = 4.16A With an L-C filter across the Input (Fig. 4) Photo 4: Remote Turn OFF (Chan 1=Enable, Chan 2=Vout) Vin=48V, Iout = 4.16A www.wallindustries.com SPW48S24-100 Page ...

Page 9

... Vin=48V, Iout = 4.167A to 2.08A Cout=0.1uF Ceramic + 10uF Tantalum (888) 597-WALL TECHNICAL DATASHEET Rev A Photo 6: Normal Turn OFF (Chan 1=Vin, Chan 2=Vout) Photo 8: Output Voltage Ripple (20 MHz BW) Cout=0.1uF Ceramic + 10uF Tantalum www.wallindustries.com SPW48S24-100 Vin=48V, Iout = 4.167A Vin=48V, Iout= 4.16A Page ...

Page 10

... WALL INDUSTRIES, INC. TEST SETUP: The SPW48S24-100 specifications are tested with the following configurations: Regulation and Efficiency Setup To ensure that accurate measurement are taken, the voltage measurements are taken directly at the terminals of the module. This minimizes errors due to contact and trace lengths between the load and the output of the supply. The following diagram is of the test setup ...

Page 11

... Airflow should be aligned lengthwise to the converter’s heatsink fins for optimum heat transfer. See Graph 2 for de-rating curves or contact factory for additional thermal information. (888) 597-WALL Rev A Figure 4: Ripple Current Setup Figure 5: Airflow Orientation www.wallindustries.com TECHNICAL DATASHEET SPW48S24-100 Page ...

Page 12

... Table 2 from each TRIM pin to ± RS pin, or alternatively, a single resistor of half the value of Table 2 from the common TRIM pins to the common ± RS pins. (888) 597-WALL Rev A , Schottky diode must be placed at the +Vo pin of each supply as shown in f Figure 6: Paralleling Converters www.wallindustries.com TECHNICAL DATASHEET SPW48S24-100 Page ...

Page 13

... Nominal Input Voltage Single Output Nominal Output Voltage Options R Phone: (603)778-2300 Toll Free: (888)587-9255 Fax: (603)778-9797 E-mail: sales@wallindustries.com Web: www.wallindustries.com Address: 5 Watson Brook Rd. Exeter, NH 03833 www.wallindustries.com TECHNICAL DATASHEET SPW48S24-100 Maximum Output Power Leave Blank for no Options Active Low Enable Page ...

Related keywords