M-FIAM5BH11 VICOR [Vicor Corporation], M-FIAM5BH11 Datasheet
M-FIAM5BH11
Related parts for M-FIAM5BH11
M-FIAM5BH11 Summary of contents
Page 1
... M = –55 to +100 – +125 *Compatible with SurfMate and InMate socketing system. H-Grade (-40°C to +100°C operation): MVA-FIAM5BH, MVA-FIAM5BH-C (On / Off control enabled) M-Grade (-55°C to +100°C operation): MVA-FIAM5BM, MVA-FIAM5BM-C (On / Off control enabled) M-FIAM5B 36 Vdc Continuous 50 Vdc See Fig ...
Page 2
... T = 25°C, nominal line and 75% load, unless otherwise specified) BP Input voltage 14 Inrush limiting Transient immunity Output current Output power Efficiency 96 Internal voltage drop External capacitance 330 ON/OFF control Enable (ON) 0.0 Disable (OFF) 3.5 Dielectric withstand MIL-STD-461E Conducted emissions: Conducted susceptibility: Weight Warranty Vicor Corp ...
Page 3
... MIL-STD-810F, Method 514.5, Procedure I, Category 14, Sine and Random vibration per Table 514.5C for Helicopter AH-6J Main Rotor with overall level of 5.6 G rms for 4 hours per axis. MIL-STD-810F, Method 514.5C, General Minimum Integrity Curve per Figure 514.5C-17 with overall level of 7.7 G rms for 1 hour per axis. ...
Page 4
... Component Suggestions Recommended Fuse: (F1 (max), Bussmann ABC style Capacitance: (C1) 330 µF (min), 1000 µF (max) Figure 5— Basic connection diagram with Transient, Surge Protection and Recommended Reverse Polarity Protection. Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Set your site on VICOR at vicorpower.com Figure 2 — ...
Page 5
... DIA,(7X) 10,16 2,03 0.700 17,78 1.000 25,40 1.400 35,56 * Slotted baseplate only ** Threaded & through hole (style 2 & 3) baseplates *** Reserved for Vicor accessories. Not for mounting C L Pin center line INBOARD ONBOARD SOLDER SOLDER MOUNT MOUNT SHORT PIN STYLE LONG PIN STYLE 0.094 ±0.003 0.094 ± ...
Page 6
... Pin Kit : The MVA-FIAM5BH and MVA-FIAM5BM are delivered with the On / Off control already configured as On using a 0 Ohm resistor on the underside of the output connector board. The MVA-FIAM5BH-C and MVA-FIAM5BM-C are delivered without the 0 Ohm resistor installed, allowing for user control of the On / Off functionality . ...
Page 7
... Vicor does not assume any liability arising out of the application or use of any product or circuit; neither does it convey any license under its patent rights nor the rights of others. Vicor general policy does not recommend the use of its components in life support applications wherein a failure or malfunction may directly threaten life or injury. Per Vicor Terms and Conditions of Sale, the user of Vicor components in life support applications assumes all risks of such use and indemnifies Vicor against all damages ...