The overflow of the Timer/Event Counter 0/1/2 is one of
the wake-up sources. The Timer/Event Counter 0/1 can
also be applied to a PFD or Programmable Frequency
Divider whose output is on pin PA3 via a configuration
option. Only one PFD (PFD0 or PFD1) can be applied to
PA3 by options. No matter what the operation mode is,
writing a 0 to ET0I, ET1I or ET2I disables the related
interrupt service. When the PFD function is selected, ex-
ecuting the SET [PA].3 instruction will enable the PFD
output and executing the CLR [PA].3 instruction will
disable the PFD output.
If the timer/event counter is not running, writing data to
the timer/event counter preload register will also reload
that data to the timer/event counter. But if the
timer/event counter running, data written to the
timer/event counter is kept only in the timer/event coun-
ter preload register. The timer/event counter continues
to operate until an overflow occurs at which point the
new data will be loaded from the preload register into the
timer/event counter.
After the timer has been initialised the timer can be
turned on and off by controlling the enable bit in the
Rev. 1.20
Timer/Event Counter 0
Timer/Event Counter 1
20
timer control register.
bit high to turn the timer on, should only be executed af-
ter the timer mode bits have been properly setup. Set-
ting the timer enable bit high together with a mode bit
modification, may lead to improper timer operation if ex-
ecuted as a single timer control register byte write in-
struction.
When the timer/event counter is read, the clock is
blocked to avoid errors. As this may results in a counting
error, blocking of the clock should be taken into account
by the programmer.
It is strongly recommended to load a desired value into
the TMR0/TMR1/TMR2 registers first, before turning on
the related timer/event counter, for proper operation
since the initial value of the TMR0/TMR1/TMR2 regis-
ters are unknown. Due to the timer/event counter
scheme, the programmer should pay special attention
to the instruction to enable then disable the timer for the
first time, whenever there is a need to use the
timer/event counter function, to avoid unpredictable re-
sult. After this procedure, the timer/event counter func-
tion can be operated normally.
HT46RU66/HT46CU66
Note that setting the timer enable
October 2, 2007