7001309-J100 Emerson Network Power, 7001309-J100 Datasheet - Page 5

no-image

7001309-J100

Manufacturer Part Number
7001309-J100
Description
Manufacturer
Emerson Network Power
Datasheet
Electrical Specifications (continued)
Output - All Models (continued)
3.3 V Outputs (Management Power)
Payload Power Interdependence
Setpoint
Total Regulation Range
Rated Load
Minimum Load
Output Rise TIme (per channel)
Output Noise (PARD)
Output Voltage Overshoot
Transient Response
Voltage Sag
Short Circuit Protection
Channel Fault Operation
(Output to Return)
Channel Fault Operation
(Output to Output)
PS1# Extraction Delay
Note 5: All channels and outputs must be confi gued by the carrier manager with the exception of MCH and CU channels and outputs
Note 6: All measurements are made at the output connector of the Power Module. Unless otherwise specifi ed,specs apply to all AMC,
MCH, and CU outputs.
which are confi gured during Startup and/or autonomous operation.
3
5,6
ENABLE# is de-asserted. The other channels
Output channel under fault is shutdown.
Both 3.3V and 12V are removed and
3.3 V must be applied before 12 V
No damage to Power Module
0.5 W / 150 mA maximum
3% maximum deviation
2 ms recovery time
150 mV maximum
225 mA maximum
50 mV maximum
75 mV maximum
100 μs maximum
25 ms maximum
12 ms maximum
3.16 to 3.63 Vdc
are not affected
3.3 Vdc typical
8 W maximum
2% maximum
No load
max of 80 W load per output or 600 W load per
onset of transient. Recovery time to within 1%
Time from de-assertion of PS1# to disabling of
Primary PM to redundant PM transition with
the channel outputs and de-assertion of the
After removal of fault, the output channel is
available again under control of the Carrier
Referenced to load current and setpoint at
Manager. PM_OK# is not de-asserted and
Removal of 3.3 V also removes 12 V
Embedded Power for
Business-Critical Continuity
With 150 μF on output under test
redundant failover is not initiated
shut down until fault is removed
of setpoint at onset of transient
Either or both channels may
37.5 mA loadstep @ 1 A/μs
and de-asserts ENABLE#
Referenced to setpoint
No loss of regulation
Per Power Module
Output to return
Per load channel
ENABLE# signal
0 to 100 MHz
0 to 30 MHz
MTC600 Series
Rev. 05.26.08
PM
5 of 19

Related parts for 7001309-J100