MAX1361EUB-T Maxim Integrated, MAX1361EUB-T Datasheet
MAX1361EUB-T
Specifications of MAX1361EUB-T
Related parts for MAX1361EUB-T
MAX1361EUB-T Summary of contents
Page 1
... Applications System Monitoring/Supervision Servers/Workstations High Reliability Power Supplies Medical Instrumentation PART TEMP RANGE MAX1361EUB+ -40°C to +85°C MAX1361MEUB+ -40°C to +85°C + Denotes a lead(Pb)-free/RoHS-compliant package. ________________________________________________________________ Maxim Integrated Products For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com. ...
Page 2
System Monitor with Programmable Trip Window and SMBus Alert Response ABSOLUTE MAXIMUM RATINGS V to GND ..............................................................-0.3V to +6V DD AIN0–AIN3, A0, REF to GND......................-0. SDA, SCL, INT to GND .............................................-0.3V to +6V Maximum Current Into ...
Page 3
System Monitor with Programmable Trip Window and SMBus Alert Response ELECTRICAL CHARACTERISTICS (continued 2.7V to 3.6V (MAX1361 0.1µ 1.7MHz SCL A MIN MAX PARAMETER SYMBOL Track/Hold ...
Page 4
System Monitor with Programmable Trip Window and SMBus Alert Response ELECTRICAL CHARACTERISTICS (continued 2.7V to 3.6V (MAX1361 0.1µ 1.7MHz SCL A MIN MAX PARAMETER SYMBOL Supply ...
Page 5
System Monitor with Programmable Trip Window and SMBus Alert Response ELECTRICAL CHARACTERISTICS (continued 2.7V to 3.6V (MAX1361 0.1µ 1.7MHz SCL A MIN MAX PARAMETER SYMBOL TIMING ...
Page 6
System Monitor with Programmable Trip Window and SMBus Alert Response ELECTRICAL CHARACTERISTICS (continued 2.7V to 3.6V (MAX1361 0.1µ 1.7MHz SCL A MIN MAX Note 1: Devices ...
Page 7
System Monitor with Programmable Trip Window and SMBus Alert Response (V = 3.3V (MAX1361 (MAX1362 +25°C, unless otherwise noted.) A SUPPLY CURRENT vs. TEMPERATURE 800 750 MAX1362 INTERNAL REFERENCE 700 ...
Page 8
System Monitor with Programmable Trip Window and SMBus Alert Response (V = 3.3V (MAX1361 (MAX1362 +25°C, unless otherwise noted.) A GAIN ERROR vs. SUPPLY VOLTAGE 1.0 0.9 0.8 0.7 0.6 ...
Page 9
System Monitor with Programmable Trip Window and SMBus Alert Response SDA t SU.DAT t LOW SCL t t SU.STA HIGH Figure 1a. F/S-Mode 2-Wire Serial-Interface Timing SDA t SU.DAT t LOW 1 SCL ...
Page 10
System Monitor with Programmable Trip Window and SMBus Alert Response The MAX1361 (2.7V to 3.6V) and MAX1362 (4.5V to 5.5V) operate from a single supply and consume 670µA (typ) at sampling rates up to 94.4ksps and 436µA in ...
Page 11
System Monitor with Programmable Trip Window and SMBus Alert Response where R is the analog-input source impedance, SOURCE R = 2.5kΩ, and C = 22pF. For internal clock mode 1.5/f , and for external ...
Page 12
System Monitor with Programmable Trip Window and SMBus Alert Response be addressed with a read command to obtain new con- version results. See the Configuration/Setup Bytes (Write Cycle) section. When configured for external clock mode (INT/EXT = 1), ...
Page 13
System Monitor with Programmable Trip Window and SMBus Alert Response S 0 SDA SCL 1 Figure 6. MAX1361/MAX1362 Slave Address Byte 2 Table Slave Selection Table A0 STATE SUFFIX Low EUB High EUB Low MEUB ...
Page 14
System Monitor with Programmable Trip Window and SMBus Alert Response START CONDITION ADDRESS START FROM THE MASTER Figure 8. Example of Writing Setup and Control Bytes START R/W BIT FROM CONDITION THE MASTER ADDRESS START FROM THE MASTER ...
Page 15
System Monitor with Programmable Trip Window and SMBus Alert Response Software Description Configuration/Setup Bytes (Write Cycle) A write cycle begins with the bus master issuing a START condition followed by 7 address bits and a write bit (R/W ...
Page 16
System Monitor with Programmable Trip Window and SMBus Alert Response Table 4. Setup-Byte Format* BIT NAME 7 (MSB) Setup Setup byte always starts with 1. When [0,0], REF/AIN3 = AIN3, REF = V 6 REF/AIN SEL1 When [0,1], ...
Page 17
System Monitor with Programmable Trip Window and SMBus Alert Response Table 8. Data Format 12 HIGH CH1 CH0 HIGH HIGH 0 = 10b 1 0/1 0 12b START ...
Page 18
System Monitor with Programmable Trip Window and SMBus Alert Response ADDRESS START FROM THE MASTER 1, CH ADD, 10b/12b, 1,1 RESULT (2 MSBs) t ACQ Figure 13. Example of Scan-Mode Conversions Using the External Clock, SCAN = 0,0 ...
Page 19
System Monitor with Programmable Trip Window and SMBus Alert Response Table 9. Monitor-Mode Setup Data Format Alarm reset, scan AIN0 thresholds speed, INT_EN , (24 bits) (8 bits) Table 10. Alarm Reset, Scan Speed Register, and INT_EN Data ...
Page 20
System Monitor with Programmable Trip Window and SMBus Alert Response Table 13. Readback-Mode Format SCAN SPEED AND INT_EN THRESHOLDS INT_EN Table 14. Reading in Monitor-Mode Data Format ALARM-STATUS REGISTER 16, 32, ...
Page 21
System Monitor with Programmable Trip Window and SMBus Alert Response Reset alarms by writing to monitor-setup data. See the Configuring Monitor Mode section and Table 10. The SMBus-alert feature provides a quick method to identify alarming devices on ...
Page 22
System Monitor with Programmable Trip Window and SMBus Alert Response SUPPLIES 4.7μ 5Ω 0.1μF V GND DD MAX1361 MAX1362 *OPTIONAL Figure 16. Power-Supply Grounding Connection MAX1361/MAX1362’s INL is measured using the end- point ...
Page 23
System Monitor with Programmable Trip Window and SMBus Alert Response PART TEMP RANGE MAX1362EUB+ -40°C to +85°C MAX1362MEUB+ -40°C to +85°C + Denotes a lead(Pb)-free/RoHS-compliant package. Typical Operating Circuit 3V/5V 0.1μ AIN0 AIN1 MAX1361 ANALOG MAX1362 ...
Page 24
... Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied. Maxim reserves the right to change the circuitry and specifications without notice at any time. 24 ____________________Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600 © 2010 Maxim Integrated Products ...