MAX1030BEEG Maxim Integrated, MAX1030BEEG Datasheet - Page 16

no-image

MAX1030BEEG

Manufacturer Part Number
MAX1030BEEG
Description
Analog to Digital Converters - ADC
Manufacturer
Maxim Integrated
Datasheet

Specifications of MAX1030BEEG

Number Of Channels
16/8
Architecture
SAR
Conversion Rate
300 KSPs
Resolution
10 bit
Input Type
Single-Ended/Differential
Snr
70 dB
Interface Type
SPI
Operating Supply Voltage
5 V
Maximum Operating Temperature
+ 85 C
Package / Case
QSOP-24
Maximum Power Dissipation
762 mW
Minimum Operating Temperature
- 40 C
Number Of Converters
1
Voltage Reference
4.096 V
10-Bit 300ksps ADCs with FIFO,
Temp Sensor, Internal Reference
Table 6. Averaging Register*
* See below for bit details.
Table 7. Reset Register
16
BIT NAME
BIT NAME
NSCAN1
NSCAN0
NSCAN1
AVGON
AVGON
NAVG1
NAVG0
RESET
______________________________________________________________________________________
0
0
1
1
0
1
1
1
1
x
x
x
NSCAN0
7 (MSB)
7 (MSB)
0 (LSB)
NAVG1
0 (LSB)
BIT
BIT
6
5
4
3
2
1
0
1
0
1
6
5
4
3
2
1
x
0
0
1
1
Set to zero to select averaging register.
Set to zero to select averaging register.
Set to 1 to select averaging register.
Set to 1 to turn averaging on. Set to zero to turn averaging off.
Configures the number of conversions for single-channel scans.
Configures the number of conversions for single-channel scans.
Single-channel scan count. (Scan mode 10 only.)
Single-channel scan count. (Scan mode 10 only.)
Scans channel N and returns 4 results.
Scans channel N and returns 8 results.
Scans channel N and returns 12 results.
Scans channel N and returns 16 results.
Set to zero to select reset register.
Set to zero to select reset register.
Set to zero to select reset register.
Set to 1 to select reset register.
Set to zero to reset all registers. Set to 1 to clear the FIFO only.
Reserved. Don’t care.
Reserved. Don’t care.
Reserved. Don’t care.
NAVG0
0
1
0
1
x
Performs 1 conversion for each requested result.
Performs 4 conversions and returns the average for each requested result.
Performs 8 conversions and returns the average for each requested result.
Performs 16 conversions and returns the average for each requested result.
Performs 32 conversions and returns the average for each requested result.
FUNCTION (APPLIES ONLY IF SCAN MODE 10 IS SELECTED)
FUNCTION
FUNCTION
FUNCTION

Related parts for MAX1030BEEG