M24C64-RMN6 STMicroelectronics, M24C64-RMN6 Datasheet - Page 13

no-image

M24C64-RMN6

Manufacturer Part Number
M24C64-RMN6
Description
EEPROM 5.5V 64K (8Kx8)
Manufacturer
STMicroelectronics
Datasheet

Specifications of M24C64-RMN6

Product Category
EEPROM
Memory Size
64 Kbit
Organization
8 K x 8
Data Retention
40 yr
Maximum Clock Frequency
0.4 MHz
Maximum Operating Current
0.8 mA
Operating Supply Voltage
1.8 V, 5.5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
SO-8
Access Time
900 ns
Interface Type
I2C
Minimum Operating Temperature
- 40 C
Factory Pack Quantity
100
Supply Voltage - Max
5.5 V
Supply Voltage - Min
1.8 V

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M24C64-RMN6P
Manufacturer:
ST
0
Part Number:
M24C64-RMN6T
Manufacturer:
ST
0
Part Number:
M24C64-RMN6TP
Manufacturer:
STMicroelectronics
Quantity:
3 500
Part Number:
M24C64-RMN6TP
Manufacturer:
ST
0
Part Number:
M24C64-RMN6TP
Manufacturer:
ST
Quantity:
256
Part Number:
M24C64-RMN6TP
Manufacturer:
ST
Quantity:
20 000
Part Number:
M24C64-RMN6TP
0
Company:
Part Number:
M24C64-RMN6TP
Quantity:
10 000
Company:
Part Number:
M24C64-RMN6TP
Quantity:
25 000
Part Number:
M24C64-RMN6TP.
Manufacturer:
ST
0
Part Number:
M24C64-RMN6TPCSA
Manufacturer:
STM
Quantity:
251
Part Number:
M24C64-RMN6TR
Manufacturer:
MIT
Quantity:
514
Part Number:
M24C64-RMN6TR
Manufacturer:
ST
0
M24C64-W M24C64-R M24C64-F M24C64-DF
4.5
Device addressing
To start communication between the bus master and the slave device, the bus master must
initiate a Start condition. Following this, the bus master sends the device select code, shown
in
Table 2.
1. The most significant bit, b7, is sent first.
2.
3. For the 5-bump WLCSP package, (E0,E1,E2) inputs are internally connected to (0,0,1)
When the device select code is received, the device only responds if the Chip Enable
address is the same as the value on its Chip Enable E2,E1,E0 inputs.
The 8
If a match occurs on the device select code, the corresponding device gives an
acknowledgment on Serial Data (SDA) during the 9
the device select code, the device deselects itself from the bus, and goes into Standby
mode.
Device select code
when addressing the
memory array
Device select code
when accessing the
Identification page
Table
E0, E1 and E2 are compared with the value read on input pins E0,E1,and E2.
th
bit is the Read/Write bit (RW). This bit is set to 1 for Read and 0 for Write operations.
2(on Serial Data (SDA), most significant bit first).
Device select code
b7
1
1
Device type identifier
Doc ID 16891 Rev 27
b6
0
0
b5
1
1
(1)
th
b4
0
1
bit time. If the device does not match
Chip Enable address
b3
E2
E2
E1
E1
b2
Device operation
b1
E0
E0
(2)(3)
RW
RW
RW
b0
13/42

Related parts for M24C64-RMN6