CAT1025WI-45-G ON Semiconductor, CAT1025WI-45-G Datasheet - Page 5

no-image

CAT1025WI-45-G

Manufacturer Part Number
CAT1025WI-45-G
Description
Supervisory Circuits CPU w/2K
Manufacturer
ON Semiconductor
Datasheet

Specifications of CAT1025WI-45-G

Product Category
Supervisory Circuits
Rohs
yes
Number Of Voltages Monitored
1
Monitored Voltage
3 V, 3.3 V, 5 V
Undervoltage Threshold
4.5 V
Overvoltage Threshold
4.75 V
Manual Reset
Resettable
Watchdog
No Watchdog
Supply Voltage - Max
5.5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
SOIC-8 Wide
Maximum Power Dissipation
1000 mW
Minimum Operating Temperature
- 40 C
Supply Current (typ)
3000 uA
Supply Voltage - Min
2.7 V
3. V
4. This parameter is tested initially and after a design or process change that affects the parameter. Not 100% tested.
5. This parameter is characterized initially and after a design or process change that affects the parameter. Not 100% tested.
6. Test Conditions according to “AC Test Conditions” table.
7. The write cycle time is the time from a valid stop condition of a write sequence to the end of the internal program/erase cycle. During the
Table 6. D.C. OPERATING CHARACTERISTICS
V
Table 7. CAPACITANCE
T
Table 8. AC CHARACTERISTICS
V
Memory Read & Write Cycle (Note 6)
C
A
write cycle, the bus interface circuits are disabled, SDA is allowed to remain high and the device does not respond to its slave address.
CC
CC
t
V
t
C
BUF
OUT
WC
IL
t
t
= 25°C, f = 1.0 MHz, V
RT
R
F
IN
Symbol
V
Symbol
Symbol
t
t
t
t
t
= 2.7 V to 5.5 V and over the recommended temperature conditions unless otherwise specified.
min and V
= 2.7 V to 5.5 V and over the recommended temperature conditions, unless otherwise specified.
HD; DAT
SU; STO
HD; STA
SU; STA
SU; DAT
(Note 5)
(Note 5)
t
RVALID
t
f
V
(Note 5)
HIGH
(Note 7)
(Note 4)
LOW
t
(Note 5)
SCL
t
t
(Note 5)
SP
AA
DH
TH
IH
max are reference values only and are not tested.
Reset Threshold
Reset Output Valid V
Reset Threshold Hysteresis
Output Capacitance
Input Capacitance
Clock Frequency
Input Filter Spike Suppression (SDA, SCL)
Clock Low Period
Clock High Period
SDA and SCL Rise Time
SDA and SCL Fall Time
Start Condition Hold Time
Start Condition Setup Time (for a Repeated Start)
Data Input Hold Time
Data Input Setup Time
Stop Condition Setup Time
SCL Low to Data Out Valid
Data Out Hold Time
Time the Bus must be Free Before a New Transmission Can Start
Write Cycle Time (Byte or Page)
CC
= 5 V
Parameter
CC
Voltage
Test
Parameter
http://onsemi.com
CAT102x−45
(V
CAT102x−42
(V
CAT102x−30
(V
CAT102x−28
(V
CAT102x−25
(V
CC
CC
CC
CC
CC
5
Test Conditions
= 5.0 V)
= 5.0 V)
= 3.3 V)
= 3.3 V)
= 3.0 V)
V
V
OUT
IN
= 0 V
Test Conditions
= 0 V
4.50
4.25
3.00
2.85
2.55
1.00
Min
15
Min
100
1.3
0.6
0.6
0.6
0.6
1.3
50
0
Typ
Max
4.75
4.50
3.15
3.00
2.70
Max
Max
400
100
300
300
900
8
6
5
Units
Units
Units
kHz
mV
ms
pF
pF
ns
ns
ns
ns
ns
ns
ns
ms
ms
ms
ms
ms
ms
V
V

Related parts for CAT1025WI-45-G