M28W320CB90N6 NUMONYX, M28W320CB90N6 Datasheet - Page 14

IC FLASH 32MBIT 90NS 48TSOP

M28W320CB90N6

Manufacturer Part Number
M28W320CB90N6
Description
IC FLASH 32MBIT 90NS 48TSOP
Manufacturer
NUMONYX
Datasheet

Specifications of M28W320CB90N6

Format - Memory
FLASH
Memory Type
FLASH
Memory Size
32M (2M x 16)
Speed
90ns
Interface
Parallel
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
48-TSOP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
497-1694

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M28W320CB90N6
Manufacturer:
ST
Quantity:
6 100
Part Number:
M28W320CB90N6
Manufacturer:
ST
Quantity:
6 100
Part Number:
M28W320CB90N6
Manufacturer:
ST
Quantity:
8 430
Part Number:
M28W320CB90N6
Manufacturer:
ST
Quantity:
215
Part Number:
M28W320CB90N6
Manufacturer:
ST
Quantity:
20 000
Part Number:
M28W320CB90N6BD
Manufacturer:
ST
Quantity:
8 470
Part Number:
M28W320CB90N6BD
Manufacturer:
ST
0
Part Number:
M28W320CB90N6D
Manufacturer:
ST
0
Part Number:
M28W320CB90N6T
Manufacturer:
ST
0
M28W320CT, M28W320CB
Register and/or the Security Block is not revers-
ible.
The Protection Register Program cannot be sus-
pended.
Block Lock Command
The Block Lock command is used to lock a block
and prevent Program or Erase operations from
changing the data in it. All blocks are locked at
power-up or reset.
Two Bus Write cycles are required to issue the
Block Lock command.
The lock status can be monitored for each block
using the Read Electronic Signature command.
Table. 9 shows the protection status after issuing
a Block Lock command.
The Block Lock bits are volatile, once set they re-
main set until a hardware reset or power-down/
power-up. They are cleared by a Blocks Unlock
command. Refer to the section, Block Locking, for
a detailed explanation.
Block Unlock Command
The Blocks Unlock command is used to unlock a
block, allowing the block to be programmed or
erased. Two Bus Write cycles are required to is-
sue the Blocks Unlock command.
14/53
The first bus cycle sets up the Block Lock
command.
The second Bus Write cycle latches the block
address.
The lock status can be monitored for each block
using the Read Electronic Signature command.
Table. 9 shows the protection status after issuing
a Block Unlock command. Refer to the section,
Block Locking, for a detailed explanation.
Block Lock-Down Command
A locked block cannot be Programmed or Erased,
or have its protection status changed when WP is
low, V
function is disabled and the locked blocks can be
individually unlocked by the Block Unlock com-
mand.
Two Bus Write cycles are required to issue the
Block Lock-Down command.
The lock status can be monitored for each block
using the Read Electronic Signature command.
Locked-Down blocks revert to the locked (and not
locked-down) state when the device is reset on
power-down. Table. 9 shows the protection status
after issuing a Block Lock-Down command. Refer
to the section, Block Locking, for a detailed expla-
nation.
The first bus cycle sets up the Block Unlock
command.
The second Bus Write cycle latches the block
address.
The first bus cycle sets up the Block Lock
command.
The second Bus Write cycle latches the block
address.