MAX1363EVKIT Maxim Integrated, MAX1363EVKIT Datasheet - Page 4

no-image

MAX1363EVKIT

Manufacturer Part Number
MAX1363EVKIT
Description
Data Conversion IC Development Tools Evaluation Kit for the MAX1361/MAX1363
Manufacturer
Maxim Integrated
Series
MAX1363, MAX1364r
Datasheet

Specifications of MAX1363EVKIT

Interface Type
I2C, Serial
Operating Supply Voltage
2.7 V to 3.6 V
The I
corner of
MAX1363 device I
MAX1361/MAX1363 device is connected to the I
bus, the user can use the I
to manually change the device’s I
in
On the right side of the I
the reference voltage information. It displays either
Internal Reference Voltage or External Reference
Voltage depending on the Setup Byte | D6 - D5 pull-
down menu setting. If the current setting is external ref-
erence mode, the user has two external reference
options as shown in
MAX1363 Evaluation Kit
Table 1. SMBus/I
*Default configuration.
4
*Default configuration.
Table 2. External Reference Selection
(JU2)
JUMPER
JUMPER
Table
_______________________________________________________________________________________
JU1
JU2
2
C Address pulldown menu shown in the top-left
1.
Figure
MAX1361EUB
MAX1363EUB
MAX1361KEUB
MAX1363KEUB
MAX1361LEUB
MAX1363LEUB
MAX1361MEUB
MAX1363MEUB
POSITION
Reference Voltage Information
SHUNT
Open*
1-2
1 autodetects the lowest MAX1361/
IC
Table
2
C address. If more than one
2
C Slave Address
2
C Address pulldown menu is
On-board external reference
connected to AIN3/REF
User-supplied external reference
to AIN3/REF
2.
2
C Address pulldown menu
Device I
POSITION
SHUNT
2
DESCRIPTION
1-2*
C address as shown
2-3
1-2
2-3
1-2
2-3
1-2
2-3
2
C Address
ADDRESS
6A
6E
6C
68
62
60
66
64
2
C
Use the Timer Interval pulldown menu to set the inter-
val value of the Auto Read timer. The choices are 0.5s,
1s, 2s, 3s, 4s, 5s, and 6s. There are two Auto Read
checkboxes that use this timer interval value. The first
Auto Read checkbox is located in the ADC Value
Display box of the main window, and the other is locat-
ed in the Reading in Monitor Mode window.
In the middle of the main window are the Setup Byte
and Configuration Byte pulldown menus and a corre-
sponding Execute button. Refer to MAX1363 data
sheet for a detailed description of the Setup Byte and
Configuration Byte registers.
If the 1 Monitor Setup is selected in the Setup Byte |
D0 pulldown menu, the Configuring Monitor Mode
window pops up as shown in
reset the channel alarm bits by checking the proper
channel in the Alarm Reset box. Select the
Scan Speed pulldown-menu setting. Enable the inter-
rupt by checking the INT_EN checkbox, and set the
LOWER and UPPER edit fields to the desired value
in the AIN_ Thresholds box. Depending on the
Setup Byte | D2 - D1 and Setup Byte | D0 pulldown-
menu settings, the threshold values for some of the
channels may be grayed out.
Whenever the Setup Byte or the Configuration Byte
pulldown-menu settings have been modified, the user
MUST PRESS the Execute button to synchronize the
software settings with the hardware.
If the Configuration Byte | D6 - D5 pulldown menu is
set to 10 SCAN1 SCAN0 Monitor Mode, the
Configuration Byte | D4 - D3 pulldown menu is set to
11 CS3 CS2 RD MON Setup, and the Execute button
is pressed, the Readback Mode window pops up. The
Readback Mode window shows the current scan
speed and alarm threshold(s). Both the Auto Read
checkbox and the Read ADC button are disabled in
this mode.
If the Configuration Byte | D6 - D5 pulldown menu is
set to 10 SCAN1 SCAN0 Monitor Mode, the
Configuration Byte | D4 - D3 pulldown menu is set to
00 CS3 CS2 Normal, and the Execute button is
pressed, the Reading in Monitor Mode window pops
up as shown in
and the Read ADC button are disabled in this mode.
Setup Byte and Configuration Byte
Figure
3. Both the Auto Read checkbox
Configuring Monitor Mode
Reading in Monitor Mode
Figure
Timer Interval
Readback Mode
2. The user can