IS45S16400E-7TLA2-TR ISSI, Integrated Silicon Solution Inc, IS45S16400E-7TLA2-TR Datasheet - Page 31

no-image

IS45S16400E-7TLA2-TR

Manufacturer Part Number
IS45S16400E-7TLA2-TR
Description
IC SDRAM 64MBIT 143MHZ 50TSOP
Manufacturer
ISSI, Integrated Silicon Solution Inc
Type
SDRAMr
Datasheet

Specifications of IS45S16400E-7TLA2-TR

Format - Memory
RAM
Memory Type
SDRAM
Memory Size
64M (4M x 16)
Speed
143MHz
Interface
Parallel
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-40°C ~ 105°C
Package / Case
50-TSOPII
Organization
4Mx16
Density
64Mb
Address Bus
14b
Access Time (max)
6/5.4ns
Maximum Clock Rate
143MHz
Operating Supply Voltage (typ)
3.3V
Package Type
TSOP-II
Operating Supply Voltage (max)
3.6V
Operating Supply Voltage (min)
3V
Supply Current
110mA
Pin Count
54
Mounting
Surface Mount
Operating Temperature Classification
Industrial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
IS45S16400E
PRECHARGE
The PRECHARGE command (see figure) is used to deac-
tivate the open row in a particular bank or the open row in
all banks.The bank(s) will be available for a subsequent row
access some specified time (t
command is issued. Input A10 determines whether one or
all banks are to be precharged, and in the case where only
one bank is to be precharged, inputs BA0, BA1 select the
bank. When all banks are to be precharged, inputs BA0,
BA1 are treated as “Don’t Care.” Once a bank has been
precharged, it is in the idle state and must be activated
prior to any READ or WRITE commands being issued to
that bank.
Integrated Silicon Solution, Inc. — www.issi.com
Rev. F
01/13/2010
POWER-DOWN
Power-down occurs if CKE is registered LOW coincident
with a NOP or COMMAND INHIBIT when no accesses
are in progress. If power-down occurs when all banks are
POWER-DOWN
idle, this mode is referred to as precharge power-down;
if power-down occurs when there is a row active in either
bank, this mode is referred to as active power-down.
Entering power-down deactivates the input and output
buffers, excluding CKE, for maximum power savings while
in standby. The device may not remain in the power-down
state longer than the refresh period (64ms) since no refresh
operations are performed in this mode.
The power-down state is exited by registering a NOP or
COMMAND INHIBIT and CKE HIGH at the desired clock
edge (meeting t
cks
COMMAND
). See figure below.
CKE
CLK
All banks idle
Enter power-down mode
rp
) after the PRECHARGE
t
NOP
CKS
Input buffers gated off
PRECHARGE Command
Exit power-down mode
BA0, BA1
A0-A9, A11
CKE
RAS
CAS
CLK
A10
WE
CS
≥ t
HIGH
CKS
NOP
DON'T CARE
BANK ADDRESS
BANK SELECT
ACTIVE
ALL BANKS
t
t
t
RCD
RAS
RC
31

Related parts for IS45S16400E-7TLA2-TR