Datasheet

Specifications of TOP227YN

Output Isolation
Isolated
Frequency Range
90 ~ 110kHz
Voltage - Output
700V
Power (watts)
150W
Operating Temperature
-40°C ~ 150°C
Package / Case
TO-220-3
Output Voltage
5.7 V
Input / Supply Voltage (max)
265 VAC
Input / Supply Voltage (min)
85 VAC
Duty Cycle (max)
70 %
Switching Frequency
100 KHz
Supply Current
1.4 mA
Operating Temperature Range
- 40 C to + 150 C
Mounting Style
Through Hole
Supply Voltage
265VAC
No. Of Pins
3
No. Of Regulated Outputs
1
Filter Terminals
Through Hole
Output Voltage Max
700V
Rohs Compliant
Yes
Operating Temperature Max
150°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
596-1163-5
TOP227YN

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
TOP227YN
Quantity:
22 000
Company:
Part Number:
TOP227YN
Quantity:
1 000
The following precautions should be followed when testing
TOPSwitch by itself outside of a power supply. The schematic
shown in Figure 14 is suggested for laboratory testing of
TOPSwitch.
When the DRAIN supply is turned on, the part will be in the
Auto-restart mode. The CONTROL pin voltage will be
oscillating at a low frequency from 4.7 to 5.7 V and the DRAIN
is turned on every eighth cycle of the CONTROL pin oscillation.
If the CONTROL pin power supply is turned on while in this
Typical Performance Characteristics
16
TOP221-227
BENCH TEST PRECAUTIONS FOR EVALUATION OF ELECTRICAL CHARACTERISTICS
CURRENT LIMIT vs. TEMPERATURE
BREAKDOWN vs. TEMPERATURE
D
7/01
1.1
1.0
0.9
1.2
1.0
0.8
0.6
0.4
0.2
0
-50 -25
-50 -25
Junction Temperature ( C)
Junction Temperature ( C)
0
0
25
25
50
50
75 100 125 150
75 100 125 150
Auto-restart mode, there is only a 12.5% chance that the control
pin oscillation will be in the correct state (DRAIN active state)
so that the continuous DRAIN voltage waveform may be
observed. It is recommended that the V
turned on first and the DRAIN power supply second if continuous
drain voltage waveforms are to be observed. The 12.5% chance
of being in the correct state is due to the 8:1 counter. Temporarily
shorting the CONTROL pin to the SOURCE pin will reset
TOPSwitch, which then will come up in the correct state.
FREQUENCY vs. TEMPERATURE
1.6
1.2
0.8
0.4
2
0
1.2
1.0
0.8
0.6
0.4
0.2
0
0
I
-50 -25
C
V C = 5 V
vs. DRAIN VOLTAGE
Junction Temperature ( C)
20
DRAIN Voltage (V)
0
40
25
50
60
75 100 125 150