Specifications of NCP1606BDR2G

Mode
Critical Conduction (CRM)
Current - Startup
20µA
Voltage - Supply
10.3 V ~ 20 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (3.9mm Width)
Output Voltage Range
0.5 V
Output Current
10 uA
Power Dissipation
800 mW
Operating Temperature Range
- 40 C to + 125 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Frequency - Switching
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
NCP1606BDR2GOSTR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NCP1606BDR2G
Manufacturer:
ON
Quantity:
3 000
Part Number:
NCP1606BDR2G
Manufacturer:
ON/安森美
Quantity:
20 000
Part Number:
NCP1606BDR2G
Manufacturer:
ON
Quantity:
9 357
Part Number:
NCP1606BDR2G
Manufacturer:
ON
Quantity:
13 742
clamp must first be overcome. This clamp will draw a
maximum of I
and allowing the ZCD pin voltage to drop low enough to
shutdown the part (Figure 39). After shutdown, the
DRIVE
To activate the shutdown feature on ZCD, the internal
Figure 37. OCP Circuitry with Optional External RC
R
Shutdown
SENSE
Figure 38. Shutting Down the PFC Stage by Pulling FB to GND (A) or Pulling ZCD to GND (B)
Shutdown
CL(NEG)
Figure 39. Shutdown Comparator and Current Draw to Overcome Negative Clamp
I
ZCD
~70 mA
R
optional
5 mA
OUT1
(5.0 mA maximum) before releasing
CS
V
OUT
Filter
R
C
OUT2
comp
LEB
+
1
2
3
4
Figure 38(a)
V
V
SDL
FB
Ctrl
Ct
Cs
CS(limit)
NCP1606
+
V
GND
DRV
ZCD
V
SDH
CC
OCP
http://onsemi.com
8
7
6
5
18
V
SHUTDOWN MODE
controller into a standby mode of operation. The FB pin can
be pulled below the UVP level (0.3 V typical) or the ZCD
pin can be pulled below the V
If the FB pin is used for shutdown (Figure 38(a)), care must
be taken to ensure that no significant leakage current exists
on the shutdown circuitry. This could impact the output
voltage regulation. If the ZCD pin is used for shutdown
(Figure 38(b)), then any parasitic capacitance created by
the shutdown circuitry will add to the delay in detecting the
zero inductor current event.
comparator includes approximately 90 mV of hysteresis to
ensure noise free operation. A small current source (70 mA
typ) is also activated to pull the unit out of the shutdown
condition when the external pull down is released.
CL(NEG)
The NCP1606 allows for two methods to place the
Figure 38(b)
1
2
3
4
L
BOOST
FB
Ctrl
Ct
Cs
NCP1606
GND
DRV
ZCD
V
CC
8
7
6
5
~1 V
SDL
R
level (typically 200 mV).
ZCD
Shutdown

Related parts for NCP1606BDR2G