NCP1338DR2G ON Semiconductor, NCP1338DR2G Datasheet
NCP1338DR2G
Specifications of NCP1338DR2G
Available stocks
Related parts for NCP1338DR2G
NCP1338DR2G Summary of contents
Page 1
... ORDERING INFORMATION Device Package Shipping† NCP1338PG PDIP−7 50 Units/Rail (Pb−Free) NCP1338DR2G SOIC−7 2500 Tape & Reel (Pb−Free) †For information on tape and reel specifications, including part orientation and tape sizes, please refer to our Tape and Reel Packaging Specification Brochure, BRD8011/D. ...
Page 2
PIN FUNCTION DESCRIPTION Pin No. Symbol Function 1 BO Brown−out and external triggering 2 FB Sets the peak current setpoint 3 CS Current sense input and overpower compensation adjustment 4 GND IC ground 5 DRV Output driver 6 VCC IC ...
Page 3
DISABLE + + Vdd BOK 500 mV OVP Skip - + 100 mV Vdd + 130 mV FB Setpoint kHz ...
Page 4
MAXIMUM RATINGS Rating Voltage on Pin 8 (HV) when Pin Decoupled to Ground with Maximum Current in Pin 8 (HV) Power Supply Voltage, Pin and Pin 5 (DRV) CC Maximum ...
Page 5
ELECTRICAL CHARACTERISTICS (For typical values unless otherwise noted.) CC Characteristic SUPPLY SECTION V Increasing Level at which the Controller Starts CC V Decreasing Level at which the Controller Stops CC Protection Mode is Activated if ...
Page 6
ELECTRICAL CHARACTERISTICS (continued) (For typical values T Max T = 150° unless otherwise noted Characteristic FEEDBACK SECTION FB Current under which FAULT is Detected FB Current for which Internal Setpoint is 100% FB Current ...
Page 7
... Dynamic Self−Supply (DSS): Due to its Very High Voltage Integrated Circuit (VHVIC) technology, ON Semiconductor’s NCP1338 allows for a direct pin connection to the high−voltage DC rail. A dynamic current source charges up a capacitor and thus provides a fully independent V ...
Page 8
V CC VCC ON VCC MIN At startup, a 4.0 ms soft−start is activated. If the current Setpoint is above the fault level, FAULT flag is raised. CS Setpoint Fault V CSstby CS V CSLimit FAULT SS TIMER When FAULT ...
Page 9
V CC VCC ON VCC MIN VCC LATCH CS Overload Setpoint Fault When the current setpoint rises above fault level, FAULT flag is activated CSLimit FAULT When FAULT flag TIMER is activated, timer is restarted ...
Page 10
VCC VCC on VCC min CS Setpoint VCS rippleOUT VCS rippleIN CS (envelope) Min T ON Soft−Skip on each re−start Figure 5. Soft−Skip Mode in Standby http://onsemi.com 10 ...
Page 11
Soxyless The “Valley point detection” is based on the observation of the Power MOSFET Drain voltage variations. When the transformer is fully demagnetized, the Drain voltage evolution from the plateau level down to the V is governed by the resonating ...
Page 12
The input information is the current injected in FB pin by the feedback loop. The range of current is from 40 mA for overload detection to 220 mA corresponding transients, currents from 0 to more than 400 ...
Page 13
V in 3.3 meg BO Rhyst 11 k Figure 8. Internal Implementation of BO Pin http://onsemi.com + Permanent Latch - + Enable + + 3 V Vdd 10 mA current source activated when V is high BOK ...
Page 14
NOTE 2 C −T− N SEATING PLANE 0.13 (0.005 −A− −B− −T− SEATING PLANE H D ...
Page 15
... SCILLC is an Equal Opportunity/Affirmative Action Employer. This literature is subject to all applicable copyright laws and is not for resale in any manner. PUBLICATION ORDERING INFORMATION LITERATURE FULFILLMENT: Literature Distribution Center for ON Semiconductor P.O. Box 5163, Denver, Colorado 80217 USA Phone: 303−675−2175 or 800−344−3860 Toll Free USA/Canada Fax: 303− ...