HCPL-2731-000E Avago Technologies US Inc., HCPL-2731-000E Datasheet - Page 7

OPTOCOUPLER DARL-OUT 2CH 8DIP

HCPL-2731-000E

Manufacturer Part Number
HCPL-2731-000E
Description
OPTOCOUPLER DARL-OUT 2CH 8DIP
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of HCPL-2731-000E

Input Type
DC
Package / Case
8-DIP (0.300", 7.62mm)
Voltage - Isolation
3750Vrms
Number Of Channels
2, Unidirectional
Current - Output / Channel
60mA
Data Rate
100KBd
Propagation Delay High - Low @ If
25µs @ 500µA
Current - Dc Forward (if)
20mA
Output Type
Open Collector
Mounting Type
Through Hole
Isolation Voltage
3750 Vrms
Output Device
Darlington With Base
Configuration
2 Channel
Current Transfer Ratio
5000 %
Maximum Baud Rate
100 KBps
Maximum Forward Diode Voltage
1.7 V
Maximum Reverse Diode Voltage
5 V
Maximum Input Diode Current
20 mA
Maximum Power Dissipation
135 mW
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
No. Of Channels
2
Optocoupler Output Type
Photodarlington
Input Current
12mA
Output Voltage
18V
Opto Case Style
DIP
No. Of Pins
8
Ctr Max
5000%
Ctr Min
300%
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
516-1543-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HCPL-2731-000E
Manufacturer:
AVAGO
Quantity:
4 000
Part Number:
HCPL-2731-000E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Insulation Related Specifications (HCPL-2731/2730/0731/0730)
Option 300 – surface mount classification is Class A in accordance with CECC 00802.
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-2, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.
7
Description
Installation Classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤600 V rms
for rated mains voltage ≤1000 V rms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
V
Partial Discharge < 5 pC
Input to Output Test Voltage, Method a*
V
t
Highest Allowable Overvoltage*
(Transient Overvoltage, t
Safety Limiting Values
(Maximum values allowed in the event of a failure, also see
Figure 11, Thermal Derating curve.)
Case Temperature
Current (Input Current I
Output Power
Insulation Resistance at T
Parameter
Minimum External Air
Gap (External Clearance)
Minimum External
Tracking (External
Creepage)
Minimum Internal Plastic
Gap (Internal Clearance)
Tracking Resistance
(Comparative Tracking
Index)
Isolation Group
P
PR
PR
= 60 sec, Partial Discharge < 5 pC
= 1.875 x V
= 1.5 x V
IORM
IORM
, Type and Sample Test,
, 100% Production Test with t
F
, P
ini
S
, V
S
= 10 sec)
= 0)
IO
= 500 V
L(101)
L(102)
Symbol
CTI
8-Pin DIP
(300 Mil)
Value
0.08
200
7.1
7.4
IIIa
P
= 1 sec,
Value
0.08
SO-8
200
4.9
4.8
IIIa
Volts
Units
mm
mm
mm
Symbol
VIORM
VPR
VPR
VIOTM
T
I
P
R
S,INPUT
S
S,OUTPUT
S
Conditions
Measured from input terminals to output
terminals, shortest distance through air.
Measured from input terminals to
output terminals, shortest distance
path along body.
Through insulation distance, conductor
to conductor, usually the direct distance
between the photoemitter and photode
tector inside the optocoupler cavity.
DIN IEC 112/ VDE 0303 Part 1
Material Group DIN VDE 0110
Characteristic
I-III
55/100/21
2
1414
2652
2121
8000
175
400
700
> 10
I-IV
9
Units
V
V
V
V
°C
mA
mW
Ω
peak
peak
peak
peak

Related parts for HCPL-2731-000E