HCPL-2430-000E Avago Technologies US Inc., HCPL-2430-000E Datasheet - Page 6

ISOLAT 3.75KVRMS 2CH UNIDIR 8DIP

HCPL-2430-000E

Manufacturer Part Number
HCPL-2430-000E
Description
ISOLAT 3.75KVRMS 2CH UNIDIR 8DIP
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of HCPL-2430-000E

Package / Case
8-DIP (0.300", 7.62mm)
Voltage - Isolation
3750Vrms
Number Of Channels
2, Unidirectional
Current - Output / Channel
25mA
Data Rate
40MBd
Propagation Delay High - Low @ If
33ns @ 7mA
Current - Dc Forward (if)
10mA
Input Type
DC
Output Type
Push-Pull, Totem-Pole
Mounting Type
Through Hole
Isolation Voltage
3750 Vrms
Maximum Continuous Output Current
25 mA
Maximum Fall Time
0.01 us
Maximum Forward Diode Current
10 mA
Minimum Forward Diode Voltage
1.1 V
Output Device
Logic Gate Photo IC
Configuration
2 Channel
Maximum Baud Rate
40 MBd(Typ)
Maximum Forward Diode Voltage
1.5 V
Maximum Reverse Diode Voltage
2 V
Maximum Power Dissipation
350 mW
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
No. Of Channels
2
Optocoupler Output Type
Logic Gate
Input Current
8mA
Output Voltage
18V
Opto Case Style
DIP
No. Of Pins
8
Body Material
2
Common Mode Ratio
1000
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
516-1539-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HCPL-2430-000E
Manufacturer:
AVAGO
Quantity:
40 000
Part Number:
HCPL-2430-000E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
6
Insulation and Safety Related Specifications
Option 300 - surface mount classification is Class A in accordance with CECC 00802.
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics
(HCPL-2400 OPTION 060 ONLY)
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section IEC/EN/DIN EN 60747-5-2 for a
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must ben ensured by protective circuits in applica-
tion.
Parameter
Minimum External
Air Gap (External
Clearance)
Minimum External
Tracking (External
Creepage)
Minimum Internal
Plastic Gap
(Internal Clearance)
Tracking Resistance
(Comparative
Tracking Index)
Isolation Group
Description
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
Input to Output Test Voltage, Method a*
Highest Allowable Overvoltage*
(Transient Overvoltage, t
Safety Limiting Values
Insulation Resistance at T
detailed description.
V
V
for rated mains voltage ≤300 V rms
for rated mains voltage ≤450 V rms
Partial Discharge < 5 pC
t
(Maximum values allowed in the event of a failure,
also see Figure 12, Thermal Derating curve.)
m
IORM
IORM
Case Temperature
Input Current
Output Power
= 60 sec, Partial Discharge < 5 pC
x 1.875 = V
x 1.5 = V
PR
, Type and sample test,
PR
, 100% Production Test with t
ini
L(101)
L(102)
S
Symbol
, V
CTI
= 10 sec)
IO
= 500 V
Value
0.08
200
IIIa
7.1
7.4
m
= 1 sec,
Volts
Units
mm
mm
mm
Conditions
Measured from input terminals to output
terminals, shortest distance through air.
Measured from input terminals to output
terminals, shortest distance path along body.
Through insulation distance, conductor to
conductor, usually the direct distance between the
photoemitter and photodetector inside the
optocoupler cavity.
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
P
Symbol
I
S,OUTPUT
V
V
S,INPUT
V
V
IORM
R
IOTM
T
PR
PR
S
S
Characteristic
55/85/21
1181
6000
≥10
630
945
175
230
600
I-IV
I-III
2
9
V
V
V
V
Units
mW
mA
°C
Ω
peak
peak
peak
peak

Related parts for HCPL-2430-000E