HCPL-J314-000E Avago Technologies US Inc., HCPL-J314-000E Datasheet - Page 6

no-image

HCPL-J314-000E

Manufacturer Part Number
HCPL-J314-000E
Description
OPTOCOUPLER 1CH 0.6A 8-DIP
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of HCPL-J314-000E

Voltage - Isolation
3750Vrms
Number Of Channels
1, Unidirectional
Current - Output / Channel
600mA
Propagation Delay High - Low @ If
300ns @ 8mA
Current - Dc Forward (if)
25mA
Input Type
DC
Output Type
Push-Pull, Totem-Pole
Mounting Type
Through Hole
Package / Case
8-DIP (0.300", 7.62mm)
No. Of Channels
1
Optocoupler Output Type
Gate Drive
Input Current
12mA
Output Voltage
30V
Opto Case Style
DIP
No. Of Pins
8
Peak Reflow Compatible (260 C)
Yes
Isolation Voltage
3.75kV
Number Of Elements
1
Forward Voltage
1.8V
Forward Current
25mA
Package Type
PDIP
Operating Temp Range
-40C to 100C
Power Dissipation
260mW
Propagation Delay Time
700ns
Pin Count
8
Mounting
Through Hole
Reverse Breakdown Voltage
3V
Operating Temperature Classification
Industrial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HCPL-J314-000E
Manufacturer:
AVAGO
Quantity:
10 000
Insulation and Safety Related Specifications
Parameter
Minimum External Air Gap
(Clearance)
Minimum External Tracking
(Creepage)
Minimum Internal Plastic Gap
(Internal Clearance)
Tracking Resistance
(Comparative Tracking Index)
Isolation Group
Absolute Maximum Ratings
Parameter
Storage Temperature
Operating Temperature
Average Input Current
Peak Transient Input Current
(<1 µs pulse width, 300pps)
Reverse Input Voltage
“High” Peak Output Current
“Low” Peak Output Current
Supply Voltage
Output Voltage
Output Power Dissipation
Input Power Dissipation
Lead Solder Temperature
Solder Reflow Temperature Profile
6
Symbol
L(101)
L(102)
CTI
Symbol
T
T
I
I
V
I
I
V
V
P
P
260°C for 10 sec., 1.6 mm below seating plane
See Package Outline Drawings section
F(AVG)
F(TRAN)
OH(PEAK)
OL(PEAK)
A
S
O
I
R
CC
O(PEAK)
- V
HCPL-J314
7.4
8.0
0.5
>175
IIIa
EE
Min.
-55
-40
-0.5
-0.5
Units
mm
mm
mm
V
Conditions
Measured from input terminals to output
terminals, shortest distance through air.
Measured from input terminals to output
terminals, shortest distance path along body.
Through insulation distance conductor to
conductor, usually the straight line distance
thickness between the emitter and detector.
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
Max.
125
100
25
1.0
5
0.6
0.6
35
V
260
105
CC
Units
°C
°C
mA
A
V
A
A
V
V
mW
mW
Note
1
2
2
3
4

Related parts for HCPL-J314-000E