HCNW138 Avago Technologies US Inc., HCNW138 Datasheet - Page 8

OPTOCOUPLER 1CH 100KBD 8-DIP

HCNW138

Manufacturer Part Number
HCNW138
Description
OPTOCOUPLER 1CH 100KBD 8-DIP
Manufacturer
Avago Technologies US Inc.
Datasheets

Specifications of HCNW138

Input Type
DC
Package / Case
8-DIP (0.400", 10.16mm)
Voltage - Isolation
3750Vrms
Number Of Channels
1, Unidirectional
Current - Output / Channel
60mA
Data Rate
100KBd
Propagation Delay High - Low @ If
1.6µs @ 1.6mA
Current - Dc Forward (if)
25mA
Output Type
Open Collector
Mounting Type
Through Hole
Isolation Voltage
5000 Vrms
Minimum Forward Diode Voltage
1.25 V
Output Device
Photodarlington
Configuration
1 Channel
Current Transfer Ratio
1500 %
Maximum Baud Rate
100 KBps
Maximum Forward Diode Voltage
1.85 V
Maximum Reverse Diode Voltage
3 V
Maximum Input Diode Current
20 mA
Maximum Power Dissipation
135 mW
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HCNW138
Manufacturer:
AVAGO
Quantity:
1 620
Part Number:
HCNW138
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Part Number:
HCNW138#500
Manufacturer:
AVAGO
Quantity:
463
Part Number:
HCNW138#500
Manufacturer:
AGILENT
Quantity:
20 000
Part Number:
HCNW138-000E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Company:
Part Number:
HCNW138-300E
Quantity:
42
Part Number:
HCNW138-500E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics (HCNW139 and HCNW138)
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN
60747-5-2, for a detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in
application.
Installation Classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
Input to Output Test Voltage, Method a*
Highest Allowable Overvoltage*
(Transient Overvoltage, t
Safety Limiting Values
Insulation Resistance at T
for rated mains voltage
for rated mains voltage
V
Partial Discharge < 5 pC
V
t
(Maximum values allowed in the event of a failure,
also see Figure 11, Thermal Derating curve.)
P
PR
PR
Case Temperature
Current (Input Current I
Output Power
= 60 sec, Partial Discharge < 5 pC
= 1.875 x V
= 1.5 x V
IORM
IORM
, Type and Sample Test,
, 100% Production Test with t
ini
S
, V
Description
= 10 sec)
600 V rms
1000 V rms
F
IO
, P
= 500 V
S
= 0)
P
= 1 sec,
P
Symbol
I
S,OUTPUT
V
V
S,INPUT
V
V
IORM
IOTM
T
R
8
PR
PR
S
S
Characteristic
55/100/21
> 10
1414
2652
2121
8000
175
400
700
I-III
I-IV
2
9
Units
V
V
V
V
mW
mA
peak
peak
peak
peak
C

Related parts for HCNW138