ACPL-4800-300E Avago Technologies US Inc., ACPL-4800-300E Datasheet - Page 5

OPTOCOUPLER IPM 5MBD 8-SMD GW

ACPL-4800-300E

Manufacturer Part Number
ACPL-4800-300E
Description
OPTOCOUPLER IPM 5MBD 8-SMD GW
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of ACPL-4800-300E

Output Type
Push-Pull, Totem-Pole
Package / Case
8-SMD Gull Wing
Voltage - Isolation
3750Vrms
Number Of Channels
1, Unidirectional
Current - Output / Channel
25mA
Data Rate
5MBd
Propagation Delay High - Low @ If
150ns @ 10mA
Current - Dc Forward (if)
10mA
Input Type
DC
Mounting Type
Surface Mount, Gull Wing
Fall Time
20 ns
Logic Gate Type
AND Schmitt
Maximum Baud Rate
5 MBps
Rise Time
16 ns
Configuration
1 Channel
Isolation Voltage
3750 Vrms
Maximum Propagation Delay Time
350 ns
Maximum Forward Diode Voltage
1.7 V
Maximum Forward Diode Current
10 mA
Maximum Operating Temperature
+ 100 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ACPL-4800-300E
Manufacturer:
AVAGO
Quantity:
3 000
Part Number:
ACPL-4800-300E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Option 300 - surface mount classification is Class A in accordance with CECC 00802.
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics (Option 060)
*
Note:
Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.
5
Insulation and Safety Related Specifications
Parameter
Minimum External Air
Gap(External Clearance)
Minimum External Track-
ing (External Creepage)
Minimum Internal Plastic
Gap (Internal Clearance)
Minimum Internal Tracking
(Internal Creepage)
Tracking Resistance
(Comparative Tracking
Index)
Isolation Group
Description
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
V
Input to Output Test Voltage, Method a*
V
Highest Allowable Over-voltage(Transient Over-voltage t
Safety-limiting values - maximum values allowed in the event of a failure.
Case Temperature
Input Current
Output Power (refer to Thermal Derating Curve)
Insulation Resistance at T
IORM
IORM
for rated mains voltage ≤ 300 V
for rated mains voltage ≤ 450 V
Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/EN/DIN
EN 60747-5-2) for a detailed description of Method a and Method b partial discharge test profiles.
x 1.875=V
x 1.5=V
PR
, Type and Sample Test, t
PR
,100% Production Test with t
S
, V
IO
Symbol
L(101)
L(102)
CTI
= 500 V
rms
rms
8-Pin DIP
7.1
7.4
0.08
NA
200
IIIa
m
=60 sec, Partial discharge < 5 pC
m
=1 sec, Partial discharge < 5 pC
Unit
mm
mm
mm
mm
ini
= 10 sec)
Conditions
Measured from input terminals to output terminals,
shortest distance through air.
Measured from input terminals to output terminals,
shortest distance path along body.
Through insulation distance, conductor to conductor,
usually the direct distance between the photo emitter
and photo detector inside the optocoupler cavity.
Measured from input terminals to output terminals,
along internal cavity.
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
Symbol
V
V
V
V
T
I
P
PUT
R
S, INPUT
S
IORM
PR
PR
IOTM
S, OUT-
S
Characteristic
I-IV
I-III
55/85/21
2
630
1181
945
6000
175
230
600
>10
9
Unit
V
V
V
V
°C
mA
mW
W
peak
peak
peak
peak

Related parts for ACPL-4800-300E