Specifications of GU280X16G-7003

Outline L X W X H
182.00mm x 33.50mm x 8.80mm
Viewing Area
137.05mm H x 11.00mm W
Display Type
Graphic
Voltage - Supply
4.75 V ~ 5.25 V
Number Of Dots
280 x 16
Interface
Serial
Operating Temperature
-40°C ~ 85°C
Description/function
Transformerless Display
Interface Type
CMOS
Data Bus Width
8 bit
Operating Voltage
5 V
Pixel Format
280 x 16
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With
286-1042 - KIT DEMO FOR 7000 SERIES VFD
Character Size
-
Display Format
-
Format
-
Lead Free Status / Rohs Status
 Details
Other names
286-1054
7.1.27
7.1.28
7.1.29
(Real-time bit image display)
Code:
Function:
Code:
n: Classify command
p: Screen saver mode
Function:
p=0~1 : Control Power ON or OFF. This is applied until this command is re-specified
p=2~4 : Start Screen saver mode. This command is canceled if next any data is inputted during
screen saver mode, and return to the previous display condition before screen saver mode
specified.
Function:
This command does not affect to display memory.
If c=0 is specified, brink display is repeated until when c=1 – 255 or Initialize command is specified,
and the command/data execution is continued during display blinking.
If c=1 – 255 is specified, brink display is repeated 1-255 times, and the command/data execution
is stopped. After display blinking is ended, return to nomal display and command/data execution
is re-started.
n:
xL:
xH:
yL:
yH:
g:
d(1) - d(k):
US ( f n [parameter]
<Function 11H> US ( f n xL xH yL yH g d(1)...d(k)
<Function 12H> US ( a n p
n: Specifies function code.
Definable area:
0 ≦ p ≦ 4
p=0: Power OFF (All dot OFF, Power save mode)
p=1: Power ON (All dot ON)
p=2: All dot OFF
p=3: All dot ON
p=4: Repeat blink display with nomal and Reverse display (Nomal :2sec., Reverse:2sec.)
1FH 28H 61H 40H p
Control Power ON or OFF, and Start Screen saver mode.
Execute processing of bit image data.
1Fh 28h 66h 11h xL xH yL yH g d(1)...d(k)
Classify command
Bit image X size lower byte ( by 1dot)
Bit image X size upper byte ( by 1dot)
Bit image Y size lower byte ( by 8dots)
Bit image Y size upper byte ( by 8dots)
Image =1(Fixed)
Blink display action Blink pattern specifed by “p”.
Time specified by “t1” , “t2”, and repeat Blink display
Image data (Refer to figure as follows)
A : t1 X approx.14msec Nomal display
B: t2 X approx. 14msec Brank or Reverse display
n = 40H
- 20 -
(Screen saver)
(Bit image display group)
11H
n
Function No.
Function 11H
Real-time bit image display
GU280X16G-7003
Function