RFS06ZE-M6 POWER ONE, RFS06ZE-M6 Datasheet - Page 13

CONV DC-DC 48V IN 3.3V OUT 19.8W

RFS06ZE-M6

Manufacturer Part Number
RFS06ZE-M6
Description
CONV DC-DC 48V IN 3.3V OUT 19.8W
Manufacturer
POWER ONE
Series
RFSr
Type
Isolatedr
Datasheet

Specifications of RFS06ZE-M6

Output
3.3V
Number Of Outputs
1
Power (watts)
20W
Mounting Type
Surface Mount
Voltage - Input
36 ~ 75V
Package / Case
18-DIP SMD Module
1st Output
3.3 VDC @ 6A
Size / Dimension
1.87" L x 1.00" W x 0.37" H (47.5mm x 25.4mm x 9.4mm)
Power (watts) - Rated
19.8W
Operating Temperature
-40°C ~ 100°C
Efficiency
85%
Approvals
CSA, EN, UL
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
179-2203
RDS Series:
Application and Auxiliary Functions
These converters do not require any external
components for proper operation. However, if the
distribution of the input voltage to the converter
contains significant inductance, a capacitor across the
input terminals may be required to stabilize the input
voltage. A minimum of 1 μF, quality electrolytic or
ceramic capacitor is recommended for this purpose.
For output decoupling it is recommend connecting a
1 μF ceramic capacitor directly across the output pins
of the converter.
Shutdown
The remote control pin functions as a normal soft
shutdown. It is referenced to the –Vi pin. With positive
logic, when the shutdown pin is pulled low, the output
is turned off, and the unit goes into a very low input
power mode. RDS models are also available with a
negative shutdown logic.
An open collector switch is recommended to control
the voltage between the shutdown pin and the -Vi pin
of the converter. The shutdown pin is pulled up
internally, so no external voltage source is required.
The user should avoid connecting a resistor between
the shutdown pin and +Vi pin.
BCD.00017 Rev. AA, 18-Oct-2010
r
®
120
100
80
60
40
20
0
0
10
Output Power vs Ambient Temperature and Airflow
0 LFM
200LFM (1 m/s)
400LFM (2 m/s)
20
30
(typically, Vi = 48 V)
Page 13 of 18
20W SMT DC-DC Converters, 1.5 – 5 V Output
40
Ambient Temp. (°C)
50
The output of the converter is enabled or disabled by
means of a logic signal (TTL, CMOS, etc.) applied to
the shutdown pin. No output voltage overshoot will
occur, when the converter is turned on. If the
shutdown function is not required, the pin should be
connected with –Vi to enable the output .
The user must take care to ensure that the pin
reference for the control is connected close to the –Vi
pin. The control signal must not be referenced ahead
of EMI filtering, or remotely from the converter. If the
shutdown pin is not used, it can be left open-circuit.
Negative Logic for RDS (
Thermal Considerations
The converter is designed for natural or forced
convection cooling. The output power of the converter
is limited by the maximum case temperature (T
ensure reliable long term operation of the converters,
and to comply with safety agency requirements,
Power-One limits maximum allowable case tempe-
rature (T
60
70
c
) to 100 °C (see Mechanical Data).
80
RFS/RDS Series Data Sheet
90
100
suffix -NM6 or -NM6G)
www.power-one.com
c
). To

Related parts for RFS06ZE-M6