CXE15-48S05 Emerson Network Power, CXE15-48S05 Datasheet

CONVERTER DC/DC 5V OUTPUT 15W

CXE15-48S05

Manufacturer Part Number
CXE15-48S05
Description
CONVERTER DC/DC 5V OUTPUT 15W
Manufacturer
Emerson Network Power
Series
CXE15r
Type
Isolatedr
Datasheet

Specifications of CXE15-48S05

Rohs Status
RoHS non-compliant
Output
5V
Number Of Outputs
1
Power (watts)
15W
Mounting Type
Through Hole
Voltage - Input
33 ~ 75V
Package / Case
6-DIP Module
1st Output
5 VDC @ 3A
Size / Dimension
2.00" L x 1.00" W x 0.35" H (50.8mm x 25.4mm x 8.9mm)
Power (watts) - Rated
15W
Operating Temperature
-40°C ~ 65°C
Efficiency
86%
Approvals
CE, cUL, TUV, UL
3rd Output
-
2nd Output
-
4th Output
-
Other names
393-1026
CXE15 Series
The CXE15 is a new high efficiency open frame isolated 15 Watt converter series
in an industry standard footprint. The CXE15 features an input voltage range of 33
Vdc to 75 Vdc and are available in output voltages of 5 V and 3.3 V. The output
voltage on each model is adjustable from 90% to 110% of the nominal value.
Typical efficiencies for the models are 87% for the 5 V and 86% for the 3.3 V. The
CXE15 series also has a remote ON/OFF capability with active high or active low
logic. Overcurrent and overvoltage protection features are included as standard.
With full international safety approval including EN60950 and cUL1950, the CXE15
reduces compliance costs and time to market.
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
DC-DC CONVERTERS
OUTPUT SPECIFICATIONS
Voltage adjustability
Total error band
Line regulation
Load regulation
Minimum load
Overshoot
Undershoot
Ripple and noise
(See Note 1)
Transient response
typ. deviation
INPUT SPECIFICATIONS
Input voltage range
Input current
Input current (max.)
Input reflected ripple
Active high remote ON/OFF
Logic compatibility
ON
OFF
Undervoltage lockout
Start-up time
(See Note 7)
High efficiency topology, 87% typical at 5 V
Industry standard footprint
Wide operating temperature, up to and exceeding 65 ˚C
(natural convection)
90% to 110% output trim
No minimum load
Overvoltage protection
Remote ON/OFF control
Available RoHS compliant
(See Note 11)
Low line to high line
Full load to min. load
5 Hz to 20 MHz
(See Note 2)
48 Vin nominal
No load
Remote OFF
(See Note 4)
(See Note 6)
Power up
Power down
Power up
Remote ON/OFF
S i n g l e o u t p u t
15 W High Efficiency DC-DC Converters
Open collector ref to -input
Open circuit or >2 Vdc
0.55 A max. @ Io max.
within total error band
and Vin = 33-75 Vdc
400 µs recovery to
5 mA (pk-pk) typ.
90% to 110%
(See Note 10)
70 mV pk-pk
1.5 ms (typ.)
2.5 ms (typ.)
±3.5% max.
35 mA max.
25 mA max.
0.1% max.
0.5% max.
20 mV rms
33-75 Vdc
33 V (typ.)
30 V (typ.)
<1.2 Vdc
100 mV
None
None
0%
EMC CHARACTERISTICS
Conducted emissions
Radiated emissions
Immunity:
ESD air
ESD contact
Radiated field enclosure EN61000-4-3 10 V/m
Conducted (dc power)
Conducted (signal)
Input transients
GENERAL SPECIFICATIONS
Efficiency
Operational insulation
Switching frequency
Approvals and
standards
(See Note 5)
Material flammability
Weight
MTBF
Representative model:
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
(See Note 9)
EN55022 (See Note 3)
EN55022 (See Note 3)
EN55022 (See Longform datasheet) Level B
EN61000-4-2 8 kV, 15 kV
EN61000-4-2 6 kV, 8 kV
EN61000-4-6 10 V
EN61000-4-6 10 V
ETS 300 132-2, ETR 283
Input/output
Fixed
MIL-HDBK-217F
48S05J @ 48 Vin, 40 °C,
100% load ground benign
BELLCORE 332
Operating ambient
temperature
Non-operating
File Name: cxe15s.pdf Rev: 01 Mar 2006
SPECIFICATIONS
UL/cUL1950, EN60950
2 YEAR WARRANTY
-40 °C to +120 °C
>1,500,000 hours
-40 °C to +65 °C
3,628,000 hours
TÜV Rheinland
12 g (0.42 oz)
265 kHz typ.
(See Note 8)
1500 Vdc
See table
UL94V-0
TÜV
Level A
Level B
1

Related parts for CXE15-48S05

CXE15-48S05 Summary of contents

Page 1

... Typical efficiencies for the models are 87% for the 5 V and 86% for the 3.3 V. The CXE15 series also has a remote ON/OFF capability with active high or active low logic. Overcurrent and overvoltage protection features are included as standard. ...

Page 2

... CAUTION: Hazardous internal voltages and high temperatures. Ensure that unit is not user accessible. REGULATION MODEL (TYP.) NUMBER LINE LOAD 86% 0.1% 0.5% CXE15-48S3V3-SJ 87% 0.1% 0.5% CXE15-48S05J Non-latching clamp ETS300-132-2, input voltage and current requirements File Name: cxe15s.pdf Rev: 01 Mar 2006 2 (10,12) Continuous ...

Page 3

... Dimensions in Inches [mm] 0.015 (0.38) 0.120 (3.05) Recommended Hole Pattern 0.800 (20.32) 0.200 Case Outline (5.08 0.400 (10.16) 1 .200(5.08) .560 (14.22) 5 .060 (1.52) 2 0.400 (10.16) 0.040 (1.016) 4 Standoff (4 places) Plated Through Hole 0.052-0.06 (1.321-1.40) typical www.artesyn.com File Name: cxe15s.pdf Rev: 01 Mar 2006 3 ...

Related keywords