JFW050A1 Lineage Power, JFW050A1 Datasheet - Page 10

no-image

JFW050A1

Manufacturer Part Number
JFW050A1
Description
CONVERTER DC/DC 5V 50W OUT
Manufacturer
Lineage Power
Series
JFWr
Type
Isolatedr
Datasheet

Specifications of JFW050A1

Output
5V
Number Of Outputs
1
Power (watts)
50W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
Module
1st Output
5 VDC @ 10A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
50W
Operating Temperature
-40°C ~ 100°C
Efficiency
84%
Approvals
CE, CSA, UL, VDE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
JFW050A1
Manufacturer:
LUCENT
Quantity:
310
dc-dc Converters; 36 to 75 Vdc Input, 5 Vdc Output; 50 W to 150 W
Test Configurations
Note: Measure input reflected-ripple current with a simulated source
Note: Use a 1.0 µF ceramic capacitor and a 10 µF aluminum or tan-
Figure 18. Peak-to-Peak Output Noise
Note: All measurements are taken at the module terminals. When
Figure 19. Output Voltage and Efficiency
10
10
BATTERY
Figure 17. Input Reflected-Ripple Test Setup
SUPPLY
V
V
η
inductance (L
tery impedance. Measure current as shown above.
talum capacitor. Scope measurement should be made using a
BNC socket. Position the load between 51 mm and 76 mm
(2 in. and 3 in.) from the module.
socketing, place Kelvin connections at module terminals to
avoid measurement errors due to socket contact resistance.
O
O
RESISTANCE
(+)
(–)
CONTACT
=
TO OSCILLOSCOPE
[
------------------------------------------------------ -
V
Measurement Test Setup
[
Measurement Test Setup
V
I
O
I
I
+ ( ) – V
+ ( ) – V
TEST
COPPER STRIP
1.0 µF
C
ESR < 0.1 Ω
@ 20 ˚C, 100 kHz
) of 12 µH. Capacitor C
S
V
V
(
220 µF
I
I
(
(+)
(
)
O
I
12 µH
– ( )
– ( )
L
SENSE(+)
SENSE(
10 µF
TEST
)
)
]I
]I
V
V
O
O
I
O
(
(+)
⎞ x 100
)
)
ESR < 0.7 Ω
@ 100 kHz
SCOPE
33 µF
DISTRIBUTION LOSSES
CURRENT
S
I
PROBE
O
offsets possible bat-
CONTACT AND
RESISTIVE
LOAD
%
8-513 (C).b
LOAD
V
V
8-203 (C).l
I
I
8-749 (C)
(+)
(–)
Design Considerations
Input Source Impedance
The power module should be connected to a low
ac-impedance input source. Highly inductive source
impedances can affect the stability of the power mod-
ule. For the test configuration in Figure 17, a 33 µF
electrolytic capacitor (ESR < 0.7 ¾ at 100 kHz)
mounted close to the power module helps ensure sta-
bility of the unit. For other highly inductive source
impedances, consult the factory for further application
guidelines.
Safety Considerations
For safety-agency approval of the system in which the
power module is used, the power module must be
installed in compliance with the spacing and separation
requirements of the end-use safety agency standard,
i.e., UL1950, CSA C22.2 No. 950-95, and VDE 0805
(EN60950, IEC950).
If the input source is non-SELV (ELV or a hazardous
voltage greater than 60 Vdc and less than or equal to
75 Vdc), for the module’s output to be considered
meeting the requirements of safety extra-low voltage
(SELV), all of the following must be true:
n
n
n
n
Note: Do not ground either of the input pins of the
The power module has extra-low voltage (ELV) outputs
when all inputs are ELV.
The input to these units is to be provided with a maxi-
mum 20 A normal-blow fuse in the ungrounded lead.
The input source is to be provided with reinforced
insulation from any hazardous voltages, including the
ac mains.
One V
both the input and output pins are to be kept floating.
The input pins of the module are not operator acces-
sible.
Another SELV reliability test is conducted on the
whole system, as required by the safety agencies, on
the combination of supply source and the subject
module to verify that under a single fault, hazardous
voltages do not appear at the module’s output.
module without grounding one of the output pins.
This may allow a non-SELV voltage to appear
between the output pin and ground.
I
pin and one V
O
pin are to be grounded or
April 2008
Lineage Power

Related parts for JFW050A1