JW050B Lineage Power, JW050B Datasheet
JW050B
Specifications of JW050B
Available stocks
Related parts for JW050B
JW050B Summary of contents
Page 1
... Description The JW050B, JW075B, JW100B, and JW150B Power Modules are dc-dc converters that operate over an input voltage range of 36 Vdc to 75 Vdc and provide a precisely regulated dc output. The outputs are fully isolated from the inputs, allowing versatile polarity configurations and grounding connections. The modules have maxi- mum power ratings from 150 typical full-load efficiency of 88% ...
Page 2
... Parameter Operating Input Voltage Maximum Input Current ( max JW050B (See Figure 1.) JW075B (See Figure 2.) JW100B (See Figure 3.) JW150B (See Figure 4.) Inrush Transient Input Reflected-ripple Current, Peak-to-peak ( MHz, 12 µH source impedance; see Figure 17.) Input Ripple Rejection (120 Hz) Fusing Considerations CAUTION: This power module is not internally fused. An input line fuse must always be used. ...
Page 3
... I JW075B I JW100B I JW150B I JW050B I O, cli JW075B I O, cli JW100B I O, cli JW150B I O, cli = 250 mV) All — η °C) JW050B C η JW075B η JW100B η JW150B All — ° max All — All — max All — All — Min ...
Page 4
... V 0 — 1.2 on/off I — — 1.0 on/off V — — 15 on/off I — — 50 on/of — — — — — 1.2 — 60 — 110 V 13.2* — 16.0* O, clamp T — 105 — C Lineage Power Unit pF M¾ Unit hr. g (oz.) Unit µ nom V °C ...
Page 5
... Converters Vdc Input, 12 Vdc Output 150 W Characteristic Curves The following figures provide typical characteristics for the power modules. The figures are identical for both on/off configurations. 2.0 1.5 1.0 0.5 0 INPUT VOLTAGE, V Figure 1. Typical JW050B Input Characteristics at Room Temperature 3.0 2.5 2.0 1.5 1.0 0.5 0 ...
Page 6
... JW050B, JW075B, JW100B, JW150B Power Modules: dc-dc Converters Vdc Input, 12 Vdc Output 150 W Characteristic Curves (continued OUTPUT CURRENT, I Figure 5. Typical JW050B Output Characteristics at Room Temperature OUTPUT CURRENT, I Figure 6. Typical JW075B Output Characteristics at Room Temperature (A) O 8-1166 (C) Figure 7. Typical JW100B Output Characteristics ...
Page 7
... Data Sheet April 2008 dc-dc Converters Vdc Input, 12 Vdc Output 150 W Characteristic Curves (continued 0.0 0.7 1.4 2.1 OUTPUT CURRENT, I Figure 9. Typical JW050B Converter Efficiency vs. Output Current at Room Temperature OUTPUT CURRENT, I Figure 10. Typical JW075B Converter Efficiency vs. Output Current at Room Temperature Lineage Power ...
Page 8
... JW050B, JW075B, JW100B, JW150B Power Modules: dc-dc Converters Vdc Input, 12 Vdc Output 150 W Characteristic Curves (continued) 12.5 A TIME µs/div) Figure 13. Typical JW150B Output Ripple Voltage at Room Temperature Input Full Load O TIME, t (50 µs/div) Note: Tested with a 10 µF aluminum and a 1.0 µF ceramic capacitor across the load ...
Page 9
... Note: Use a 1.0 µF ceramic capacitor and a 10 µF aluminum or tantalum capacitor. Scope measurement should be made using a BNC socket. Position the load between 51 mm and in. and 3 in.) from the module. Figure 18. Peak-to-Peak Output Noise Measurement Test Setup Lineage Power JW050B, JW075B, JW100B, JW150B Power Modules: CURRENT PROBE SUPPLY V (+) I CONTACT 33 µ ...
Page 10
... JW050B, JW075B, JW100B, JW150B Power Modules: dc-dc Converters Vdc Input, 12 Vdc Output 150 W the input and output pins are to be kept floating The input pins of the module are not operator acces- sible. Another SELV reliability test is conducted on the whole system, as required by the safety agencies, on ...
Page 11
... RESISTANCE Figure 21. Effective Circuit Configuration for Single-Module Remote-Sense Operation Lineage Power JW050B, JW075B, JW100B, JW150B Power Modules: Output Voltage Set-Point Adjustment (Trim) Output voltage trim allows the user to increase or decrease the output voltage set point of a module. This is accomplished by connecting an external resistor between the TRIM pin and either the SENSE(+) or SENSE(– ...
Page 12
... JW050B, JW075B, JW100B, JW150B Power Modules: dc-dc Converters Vdc Input, 12 Vdc Output 150 W Feature Descriptions (continued) Output Voltage Set-Point Adjustment (Trim) (continued) V (+) V (+) I O ON/OFF SENSE(+) CASE TRIM V (–) SENSE(– (–) O Figure 22. Circuit Configuration to Decrease Output Voltage 1M 100k 10k ...
Page 13
... Series 150 W Board-Mounted Power Modules Technical Note (TN97-008EPS). Lineage Power JW050B, JW075B, JW100B, JW150B Power Modules: Heat Transfer Without Heat Sinks Increasing airflow over the module enhances the heat transfer via convection. Figure 27 shows the maximum power that can be dissipated by the module without ...
Page 14
... JW050B, JW075B, JW100B, JW150B Power Modules: dc-dc Converters Vdc Input, 12 Vdc Output 150 W Thermal Considerations Heat Transfer Without Heat Sinks 0.00 0.42 0.84 1.26 1.68 2.10 2.52 OUTPUT CURRENT, I Figure 28. JW050B Power Dissipation vs. Output Current 0.000 1.250 2.500 3.750 0.625 1.875 3 ...
Page 15
... The module used to collect the data in Figure 32 had a Lineage Power JW050B, JW075B, JW100B, JW150B Power Modules: thermal-conductive dry pad between the case and the (continued) heat sink to minimize contact resistance. The use of Figure 32 is shown in the following example ...
Page 16
... JW050B, JW075B, JW100B, JW150B Power Modules: dc-dc Converters Vdc Input, 12 Vdc Output 150 W Thermal Considerations Custom Heat Sinks (continued) For a managed interface using thermal grease or foils, a value 0.1 °C/W to 0.3 °C/W is typical. The solution for heat sink resistance is – – ------------------------ - ...
Page 17
... Side label includes Lineage name, product designation, safety agency markings, input/output voltage and current ratings, and bar code. Lineage Power JW050B, JW075B, JW100B, JW150B Power Modules: 57.9 (2.28) MAX 61.0 (2.40) MAX SIDE LABEL* 1.02 (0.040) DIA ...
Page 18
... JW050B, JW075B, JW100B, JW150B Power Modules: dc-dc Converters Vdc Input, 12 Vdc Output 150 W Recommended Hole Pattern Component-side footprint. Dimensions are in millimeters and (inches). 35.56 (1.400) 50.8 25.40 (2.00) (1.000) 5.1 (0.20) Ordering Information Table 4. Device Codes Input Output Voltage Voltage ...
Page 19
... Dimensions are in millimeters and (inches). 1/4 IN. 1/2 IN. 1 IN. 61 (2.4) 1 1/2 IN. 57.9 (2.28) Figure 34. Longitudinal Heat Sink Lineage Power JW050B, JW075B, JW100B, JW150B Power Modules: 61 (2.4) D000-c.cvs Figure 35. Transverse Heat Sink Comcode 407243989 407243997 407244706 407244714 407244722 407244730 ...
Page 20
... Lineage P ower r eserves the right to mak e c hanges to the produc t(s) or information contained her ein without notice. No liability is ass umed ult of their use or applic ation. No rights under any patent accompany the sale of any product information. © 2008 Lineage Power Corpor ation, (Mesquite International Rights Res er ved. April 2008 ...