BXA30-48T05-12 Emerson Network Power, BXA30-48T05-12 Datasheet

no-image

BXA30-48T05-12

Manufacturer Part Number
BXA30-48T05-12
Description
CONVERTER DC/DC TRPL 5V OUT 30W
Manufacturer
Emerson Network Power
Series
BXA30r
Type
Isolatedr
Datasheet

Specifications of BXA30-48T05-12

Rohs Status
RoHS non-compliant
Output
5V, ±12V
Number Of Outputs
3
Power (watts)
30W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
8-DIP Module
1st Output
5 VDC @ 3A
2nd Output
12 VDC @ 625mA
3rd Output
-12 VDC @ 625mA
Size / Dimension
3.02" L x 2.41" W x 0.52" H (76.3mm x 61.1mm x 13.3mm)
Power (watts) - Rated
30W
Operating Temperature
-25°C ~ 100°C
Efficiency
83%
Approvals
CE, CSA, UL, VDE
4th Output
-
BXA30 Series
The BXA30 triple output Series, comprising 2 different models, has been conceived as an
applications-specific range of DC/DC converters, specifically addressing telecommunications,
industrial electronics, test equipment, mobile telecommunications and distributed power
applications. The series offers two wide input voltage ranges, 18-36VDC and 36-75VDC.
Designed to meet ETSI telecoms interface standards ETS300-132-2 and BTR2511, together
with internal filtering to EN55022 level A, safety approval to EN60950 and UL1950, and basic
insulation of 1500VDC, the 48VDC model is ideal for telecommunications applications.
The 24V model is particularly suited to industrial, mobile telecom and test equipment
applications, featuring EN61000-4-2, -3, -4, -5 and -6 immunity compliant. Other features
include low output ripple, overvoltage protection, short circuit protection, remote enable.
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
DC/DC CONVERTERS
OUTPUT SPECIFICATIONS
Output power
Line regulation
(See Note 1)
Load regulation
(See Note 2)
Ripple and noise
(20MHz bandwidth)
Temperature coefficient
Overvoltage protection
Short circuit protection
Transient response
Voltage accuracy
Load cross regulation
Minimum load
(See Note 10)
INPUT SPECIFICATIONS
Input voltage range
Reverse voltage prot.
Max. input rise and
fall time
Remote ON/OFF
Logic compatibility
ON
OFF
Pin-compatible with BXA15 series
Designed to meet telecom power supply interface
standard ETS300-132-2
UL, CSA and VDE approvals
VDE0878 and EN55022 conducted emissions level A
EN61000-4-2, -3, -4, -5, -6 immunity compliant
Fixed frequency operation at 350kHz
MTBF in excess of 7,005,000 hours (demonstrated)
Basic insulation system
Main output
Auxiliary output
Main output
Auxiliary output
Main output
Auxiliary outputs
Transient, all outputs
All outputs
(See BXA15/30 Design Note 101)
25% to 100% load, all outputs
Main output
Auxiliary output
20% to 100% load
Main: output
Auxiliary: output
50% to 100% load, main, >20% aux.
Main output
Auxiliary output
Main output for auxiliary
regulation
24Vin nominal
48Vin nominal
(See Note 6)
48V
T r i p l e o u t p u t
30W Wide Input DC/DC Converters
135% Vout init.
100mV pk-pk
18 to 36VDC
36 to 75VDC
ETS300-132
75mV pk-pk
Open circuit
±0.02%/°C
CMOS/TTL
15mV rms
20mV rms
<1VDC
±0.5%
±2.0%
±1.0%
±3.0%
±1.5%
±3.0%
5V/ms
>10%
1.0%
1.0%
4.0%
10%
10%
30W
Yes
Yes
EMC CHARACTERISTICS
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
GENERAL SPECIFICATIONS
Efficiency
Isolation voltage
Basic insulation
Switching frequency
Approvals and
standards
(See Note 11)
Case material
Material flammability
Weight
MTBF (See Note 9)
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Thermal impedance
EN55022, FCC part 15 (Note 3) Level A
EN55022, FCC part 15 (Note 4) Level B
VDE0878 (Note 3) (48V)
EN55022, FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-5, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
Input/output
Input/case, 48V models
Fixed
Demonstrated @ 25°C
Baseplate operating
temperature,
(See Notes 5, 7)
Non-operating
Free air convection,
baseplate to air
With heatsink (See Note 7)
File Name: BXA30T.PDF Rev: 02 Oct 2002
EN41003, IEC950, UL1950
SPECIFICATIONS
2 YEAR WARRANTY
Aluminum substrate
VDE0805, EN60950
CSA C22.2 No. 950
-25°C to +100°C
-55°C to +100°C
with plastic case
7,005,000 hours
Perf. criteria 2
Perf. criteria 2
Perf. criteria 2
Perf. criteria 2
Perf. criteria 2
Perf. criteria 2
350kHz, nom.
130g (4.6oz)
See table
1500VDC
1500VDC
UL94V-0
6.5°C/W
5.2°C/W
Level A
Level A
1

Related parts for BXA30-48T05-12

BXA30-48T05-12 Summary of contents

Page 1

... MTBF in excess of 7,005,000 hours (demonstrated) • Basic insulation system The BXA30 triple output Series, comprising 2 different models, has been conceived as an applications-specific range of DC/DC converters, specifically addressing telecommunications, industrial electronics, test equipment, mobile telecommunications and distributed power applications. The series offers two wide input voltage ranges, 18-36VDC and 36-75VDC. ...

Page 2

... An optional internal filter is available, which will meet VDE0871 level A, VDE0878 level A and EN55022 level A. Add the suffix ‘-F’ to the model number, e.g. BXA30-48T05-12-F. See BXA15 and BXA30 Design Note 100. 4 For conducted noise operation of the BXA30 to VDE0871, VDE0878 and EN55022 level B, see BXA15 and BXA30 Design Note 100 ...

Related keywords