Specifications of OKL-T/6-W5N-C

Number Of Outputs
1
Output
0.6 ~ 3.3V
Power (watts)
19.8W
Mounting Type
Surface Mount
Voltage - Input
2.4 ~ 5.5 V
Package / Case
12-SMD Module
1st Output
0.6 ~ 3.3 VDC @ 6A
Size / Dimension
0.48" L x 0.48" W x 0.28" H (12.2mm x 12.2mm x 7.1mm)
Power (watts) - Rated
19.8W
Operating Temperature
-40°C ~ 85°C
Efficiency
93.5%
Approvals
CSA, cUL, EN, IEC, UL
Output Power
19.8 W
Input Voltage Range
2.4 V to 5.5 V
Input Voltage (nominal)
5 V
Package / Case Size
12.2 mm x 12.2 mm x7.2 mm
Output Voltage
0.6 V to 3.3 V
Product
Non-Isolated / POL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
811-2213-2
Specifi cation Notes, Cont.:
(6)
(7)
(8)
(9)
(10) Regulation specifi cations describe the deviation as the line input voltage or output load current is varied from a
(11) Other input or output voltage ranges will be reviewed under scheduled quantity special order.
(12) Maximum PC board temperature is measured with the sensor in the center of the converter.
(13) Do not exceed maximum power specifi cations when adjusting the output trim.
Short circuit shutdown begins when the output voltage degrades approximately 2% from the selected setting.
Please observe the voltage input and output specifi cations in the Voltage Range Graph on page 7.
Output noise may be further reduced by adding an external fi lter. At zero output current, the output may contain
low frequency components which exceed the ripple specifi cation. The output may be operated indefi nitely with
no load.
All models are fully operational and meet published specifi cations, including “cold start” at –40˚ C.
nominal midpoint value to either extreme.
www.murata-ps.com
(14) The maximum output capacitive loads depend on the the Equivalent Series Resistance (ESR) of the external
(15) Do not allow the input voltage to degrade lower than the input undervoltage shutdown voltage at all times.
(16) The outputs are not intended to sink appreciable reverse current.
(17) “Hiccup” overcurrent operation repeatedly attempts to restart the converter with a brief, full-current output. If
output capacitor and, to a lesser extent, the distance and series impedance to the load. Larger caps will reduce
output noise but may change the transient response. Newer ceramic caps with very low ESR may require lower
capacitor values to avoid instability. Thoroughly test your capacitors in the application. Please refer to the Output
Capacitive Load Application Note.
Otherwise, you risk having the converter turn off. The undervoltage shutdown is not latching and will attempt to
recover when the input is brought back into normal operating range.
the overcurrent condition still exists, the restart current will be removed and then tried again. This short current
pulse prevents overheating and damaging the converter. Once the fault is removed, the converter immediately
recovers normal operation.
Programmable Output 6-Amp iLGA SMT PoLs
28 Mar 2011 MDC_OKL-T/6-W5 Series.A07 Page 4 of 17
OKL-T/6-W5 Series
email: sales@murata-ps.com