PXF4012S05 TDK Corporation, PXF4012S05 Datasheet - Page 2

DC-DC CONVERTERS 5V 8A

PXF4012S05

Manufacturer Part Number
PXF4012S05
Description
DC-DC CONVERTERS 5V 8A
Manufacturer
TDK Corporation
Series
PXFr
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheets

Specifications of PXF4012S05

Output
5V
Number Of Outputs
1
Power (watts)
40W
Mounting Type
Through Hole
Voltage - Input
9 ~ 18V
Package / Case
9-DIP Module
1st Output
5 VDC @ 8A
Size / Dimension
2.00" L x 2.00" W x 0.40" H (50.8mm x 50.8mm x 8.6mm)
Power (watts) - Rated
40W
Operating Temperature
-40°C ~ 100°C
Efficiency
86%
Approvals
CE, CSA, EN, UL
Dc / Dc Converter O/p Type
Fixed
No. Of Outputs
1
Input Voltage
9V To 18V
Power Rating
40W
Output Voltage
5V
Output Current
8A
Approval Bodies
UL, CSA, CE
Supply Voltage
18V
Brand/series
PXF Series
Configuration
Enclosed
Current, Output
3.333 A
Dimensions
2 in. L x 2 in. W x 0.4 in. H
Operation
Switching
Power, Output
40 W
Primary Type
DC-DC Converter
Special Features
Remote On/Off
Standards
UL Listed, CSA Certified, EN and CE Approvals
Voltage, Input
9 to 18 VDC
Voltage, Input Range
9 to 18 VDC
Voltage, Output
5 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1555
PXF40-12S05
Block Diagram
EMI Filter (Optional)
Input filter components (C1, C2, L1) are used to help meet special
conducted emissions requirements for the PXF product. These
components should be mounted as close as possible to the DC-
DC converter; and all leads should be minimized to decrease
radiated noise.
Minimum Load
A 10% (of full load) minimum load is required to meet the
performance specifications. The unit does not maintain regulation
and operate properly under a no-load condition.
Pin Assignments
Pin
1
2
3
4
5
6
7
8
9
PXF40
Connection
+ Input
- Input
Remote On / Off
No Pin
- Sense (*)
+ Sense (*)
+ Output
- Output
Trim
System Ground
Source
DC
+
-
1µF, MLC
C1
Fuse
C1
*
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
If remote sense is not being used, the
+Sense and - Sense should be
connected to their corresponding
outputs; + output, -output.
Optional
Filter
EMI
L1
5.5µH
L1
Appropriate hook-up location for
test equipment to monitor output.
C2
39µF 100V
Electrolytic
+Vin
-Vin
Remote On / Off
C2
Installation Data Sheet
PXF
Trim
Outline Drawing
Pin Diameter: 1mm (0.04")
+Vo
-Vo
1uf
DVM
Load
Coax cable
0.1uf
50Ω
Oscilloscope

Related parts for PXF4012S05