S8VS-18024 Omron, S8VS-18024 Datasheet - Page 15

POWER SUPPLY SW 24VDC 7.5A 180W

S8VS-18024

Manufacturer Part Number
S8VS-18024
Description
POWER SUPPLY SW 24VDC 7.5A 180W
Manufacturer
Omron
Series
S8VSr
Datasheets

Specifications of S8VS-18024

Voltage - Output
24V
Number Of Outputs
1
Power (watts)
180W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
100 ~ 240VAC
Mounting Type
DIN Rail
1st Output
24 VDC @ 7.5A
Size / Dimension
4.93" L x 2.95" W x 4.53" H (125.3mm x 75mm x 115mm)
Power (watts) - Rated
180W
Operating Temperature
-10°C ~ 60°C
Efficiency
80%
Approvals
CE, CSA, cUL, EN, UL, VDE
Product
Switching
Output Power Rating
180 W
Input Voltage
100 VAC to 240 VAC
Output Voltage (channel 1)
24 V
Output Current (channel 1)
7.5 A
Mounting Style
DIN Rail
Dimensions
125.3 mm L x 75 mm W x 115 mm H
Open Frame/enclosed
Enclosed
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
S8VS18024
Z2298
Mounting
Note: 1. Improper mounting will interfere with heat dissipation and
Overload Protection
The load and the power supply are automatically protected from
overcurrent damage by this function.
Overload protection is activated if the output current rises above
105% of the rated current.
When the output current returns within the rated range overload
protection is automatically cleared.
Note: 1. Internal parts may occasionally deteriorate or be damaged
Standard mounting with DIN rail
Standard mounting with S82Y-VS30P
Note: The Side-mounting Bracket can be mounted from either side.
Horizontal mounting with S82Y-VS30P*
2. Use a mounting bracket (S82Y-VS30P, sold separately)
3. Heat dissipation will be adversely affected. When the
4. Use PFP-M End Plates on the top and bottom of the Power
2. Internal parts may possibly deteriorate or be damaged if the
0
15-W Models
The values shown in the above diagrams are for reference only.
may occasionally result in deterioration or damage of
internal parts. Use the Product within the derating curve for
the mounting direction that is used. Do not use the Power
Supply mounted in any way not shown above.
when the Product is mounted horizontally.
Product is mounted facing horizontally, always place the
side with the label facing horizontally.
Supply when mounting horizontally on a DIN rail.
if a short-circuited or overcurrent state continues during
operation.
Power Supply is used for applications with frequent inrush
current or overloading at the load end. Do not use the Power
Supply for such applications.
50
Output current (%)
100
S82Y-VS30P
Side with label
Face-up
Face-up
0
30-W Models
mounting with DIN rail
mounting with S82Y-VS30P
Intermittent
operation
50
Output current (%)
100
Overvoltage Protection
Consider the possibility of an overvoltage and design the system so
that the load will not be subjected to an excessive voltage even if the
feedback circuit in the Power Supply fails.
This power supply automatically protects itself and the load from
overvoltage.
Overvoltage protection is activated if the output voltage rises above
approx. 130% of the rated output voltage.
To reset the power supply, leave the power supply off for more than
3 minutes and then turn it on again.
Note: 1. Do not turn ON the power again until the cause of the
Inrush Current, Startup Time, Output Hold Time
Undervoltage Alarm Indication
LED (DC LOW: red) lights to warn of output voltage drop.
Detection voltage is set to approx. 80% (75 to 90%) of the rated output
voltage.
Note: This function monitors the voltage at the power supply output
AC input
voltage
AC input
current
Output
voltage
Rated output
2. The overvoltage protection of the S8VS-015@@ uses a
terminals. To check actual voltage, measure voltage on the
load side.
The values shown in the above diagram is for reference only.
(approx.)
overvoltage has been removed.
zener diode clamp. The output voltage will be clamped at
approx. 140% or higher of the rated output voltage. If the
internal feedback circuit is destroyed by any chance, the
load may be destroyed by the clamped output voltage
(approx. 140% to 190% of the rated output voltage). The
power Supply will not restart if the output is turned OFF by
the overvoltage protection operation. If this occurs, replace
the Power Supply.
voltage
Input ON
+30%
+15%
−10%
0 V
Inrush current on input application
Startup time (1,000 ms max.)
Variable range
Overvoltage protection
operating
90%
Hold time
(20 ms min.)
Input OFF
S8VS
96.5%
15