S8VS-24024A Omron, S8VS-24024A Datasheet - Page 18

POWER SUPPLY SW 24VDC 10A W/DISP

S8VS-24024A

Manufacturer Part Number
S8VS-24024A
Description
POWER SUPPLY SW 24VDC 10A W/DISP
Manufacturer
Omron
Series
S8VSr
Datasheet

Specifications of S8VS-24024A

Power Supply Type
Switching (Closed Frame)
Input Voltage
100 VAC to 240 VAC
Voltage - Output
24V
Number Of Outputs
1
Power (watts)
240W
Applications
Commercial
Voltage - Input
100 ~ 240VAC
Mounting Type
DIN Rail
1st Output
24 VDC @ 10A
Size / Dimension
4.93" L x 3.94" W x 4.53" H (125.3mm x 100mm x 115mm)
Power (watts) - Rated
240W
Operating Temperature
-10°C ~ 60°C
Efficiency
80%
Approvals
CE, CSA, cUL, EN, UL, VDE
Product
Switching
Commercial/medical
Both
Output Power Rating
240 W
Output Voltage (channel 1)
24 V
Output Current (channel 1)
10 A
Mounting Style
DIN Rail
Dimensions
125.3 mm L x 115 mm W x 100 mm H
Open Frame/enclosed
Enclosed
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
24V
Output Current
10A
Power Rating
240W
Length
125.3mm
Width
100mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
S8VS24024A
Z2302
Mode Change (S8VS-@@@24A@@/S8VS-@@@24B@@/S8VS-@@@24BE@ Only)
S8VS-@@@24A@@ models (with display monitor) can display the output voltage, output current, peak hold current, or maintenance forecast
monitor time. S8VS-@@@24B@@/S8VS-@@@24BE@ models (with display monitor) can display the output voltage, output current, peak hold
current, or total run time.
Note: No setting mode is provided for the S8VS-06024@.
Operation Mode
Various states of the Power Supply are indicated.
Note: 1. The peak hold current starts measuring the current 3 seconds after the Power Supply is started. Inrush current is thus not measured.
Setting Mode (Except for S8VS-06024@)
Set various parameters of the Power Supply.
Note: 1. Press and hold the (9) Up Key U or (10) Down Key D for two seconds or more to increase or decrease the value rapidly.
Press and hold
Up key
for three seconds or more.
Models with Maintenance Forecast Monitor (S8VS-@@@24A@@)
Models with Maintenance Forecast Monitor (S8VS-@@@24A@@)
Undervoltage
detected
Operation Mode
Maintenance
forecast
2. For the factory setting, the output voltage will be displayed when the power supply is first turned ON. Thereafter, the output voltage will
2. The S8VS-06024@ is not provided with the setting mode and its parameters are fixed at the shipment setting.
Press 3 seconds
or more.
U
be indicated in the same display when shutting down.
or Down Key
or
Operation mode
D
Setting mode
Power-ON
Maintenance forecast monitor
Output voltage
(Voltage output by Power Supply is
monitored and displayed.)
Output current
(Current output by Power Supply is
monitored and displayed.)
Peak hold current (See note 1.)
(Maximum current output by Power Supply is
recorded and displayed.)
pressed for 30 seconds or more.
Model indication
Press Mode key
hold for three seconds or more.
Or no key operation for 30 seconds or more.
Press 3 seconds or more or no key
/
/
* Factory settings are in reverse
0.1-V steps
0.5-year steps
18.5 to
0.0 to
type.
and
0.5
20.0
*
*
to 5.0 (y)
to 27.5 (V)
Models with Total Run Time Monitor (S8VS-@@@24B@@/S8VS-@@@24BE@)
Undervoltage
detected
Total run
time
Operation Mode
Models with Total Run Time Monitor (S8VS-@@@24B@@/
S8VS-@@@24BE@)
Press 3 seconds
or more.
o r
Total run time monitor
pressed for 30 seconds or more.
Output voltage
(Voltage output by Power Supply is
monitored and displayed.)
Output current
(Current output by Power Supply is
monitored and displayed.)
Peak hold current
(Maximum current output by Power Supply is
recorded and displayed.)
Press 3 seconds or more or no key
/
/
* Factory settings are in
0.1-V steps
1,000-hour steps
1 to
18.5 to
reverse type.
50
*
to 150 ( × 1000 h)
20.0
*
S8VS
to 27.5 (V)
18

Related parts for S8VS-24024A