S8VS-24024A Omron, S8VS-24024A Datasheet - Page 19

POWER SUPPLY SW 24VDC 10A W/DISP

S8VS-24024A

Manufacturer Part Number
S8VS-24024A
Description
POWER SUPPLY SW 24VDC 10A W/DISP
Manufacturer
Omron
Series
S8VSr
Datasheet

Specifications of S8VS-24024A

Power Supply Type
Switching (Closed Frame)
Input Voltage
100 VAC to 240 VAC
Voltage - Output
24V
Number Of Outputs
1
Power (watts)
240W
Applications
Commercial
Voltage - Input
100 ~ 240VAC
Mounting Type
DIN Rail
1st Output
24 VDC @ 10A
Size / Dimension
4.93" L x 3.94" W x 4.53" H (125.3mm x 100mm x 115mm)
Power (watts) - Rated
240W
Operating Temperature
-10°C ~ 60°C
Efficiency
80%
Approvals
CE, CSA, cUL, EN, UL, VDE
Product
Switching
Commercial/medical
Both
Output Power Rating
240 W
Output Voltage (channel 1)
24 V
Output Current (channel 1)
10 A
Mounting Style
DIN Rail
Dimensions
125.3 mm L x 115 mm W x 100 mm H
Open Frame/enclosed
Enclosed
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
24V
Output Current
10A
Power Rating
240W
Length
125.3mm
Width
100mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
S8VS24024A
Z2302
Peak Hold Current Reset
The peak value of the output current (i.e., the peak hold current) can
be reset on the display.
Note: The peak hold current value is not reset in the setting mode.
Undervoltage Alarm Indication
This indicator lights when the output voltage lowers.
Note: 1. When the voltage is restored to the set value or higher and
Operation mode
Reset
Peak hold current
value measurement
starts
Operation
Mode
Undervoltage
alarm
Output
current
Peak-hold
current
Maintenance
forecast
monitor
2. The above displays are for models with a maintenance
the
output current display, the a01 alarm will be cleared and the
normal output display will return.
forecast monitor (S8VS-@@@24A@@).
Key is pressed at the a01 display to return to the
Undervoltage occurs.
2 seconds (Peak hold current will be displayed
Key Press 3 seconds or more.
2 seconds after it is reset.)
*
*This indicator alternately
Output voltage lower limit
displays alarm (
the output voltage lower
limit.
) and
Multiple Alarms
When two or more different alarms occur at the same time
* When undervoltage alarm is indicated: Press
Note: 1. The above displays are for models with a maintenance
Operation
Mode
Undervoltage
alarm
Maintenance
forecast
monitor
load indication
When the maintenance forecast monitor or overheat alarm is
indicated: Press
forecast monitor (S8VS-@@@24A@@).
Key → undervoltage alarm indication
(See note.)
(See note.)
The indication shifts
alternately in the direction
of the arrow every 2 s.
Key → output
S8VS
19

Related parts for S8VS-24024A