BLP55-3300G POWER ONE, BLP55-3300G Datasheet - Page 2

PWR SUP 55W 3.3V,5V,12V OUT TRPL

BLP55-3300G

Manufacturer Part Number
BLP55-3300G
Description
PWR SUP 55W 3.3V,5V,12V OUT TRPL
Manufacturer
POWER ONE
Series
BLP55r
Type
Switchingr
Datasheets

Specifications of BLP55-3300G

Voltage - Output
3.3V, 5V, 12V
Number Of Outputs
3
Power (watts)
55W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
100 ~ 250VAC
Mounting Type
Chassis Mount
1st Output
3.3 VDC @ 7A
2nd Output
5 VDC @ 4A
3rd Output
12 VDC @ 1A
Size / Dimension
5" L x 3" W x 1.23" H (127mm x 76.2mm x 31.2mm)
Power (watts) - Rated
55W
Operating Temperature
0°C ~ 70°C
Efficiency
70%
Approvals
CB, CE, CSA, EN, IEC, UL
Line Regulation
±2.5%, ±5%
Load Regulation
±2.5%, ±5%
Input Voltage
85 to 264 V
Output Voltage
3.3|5|12 V
Maximum Current Rating
1(rms)(Typ) A
Maximum Output Current
4|2|0.5 A
Maximum Output Power
25 W
Input Frequency
47 to 63 Hz
Product
Switching
Commercial/medical
Commercial
Output Power Rating
17 W
Output Voltage (channel 1)
3.3 V
Output Current (channel 1)
5 A
Output Voltage (channel 2)
5 V
Output Current (channel 2)
2.5 A
Output Voltage (channel 3)
12 V
Output Current (channel 3)
0.7 A
Mounting Style
Chassis
Dimensions
127 mm L x 76.2 mm W x 31.2 mm H
Open Frame/enclosed
Open Frame
Brand/series
BLP55 Series
Configuration
Open-Frame
Operation
Switching
Output
+3.3 VDC @ 4 A, +5 VDC @ 2 A, +12 VDC @ 0.5 A
Power, Output
55 W
Primary Type
AC-DC
Special Features
Remote Sense
Voltage, Input
100 to 250 VAC
Voltage, Output
+3.3, +5, +12 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
179-2268
Input Specifications
PARAMETER
Input Voltage - AC
Input Voltage - DC
Input Frequency
Input Current
Inrush Surge Current
Input Fuse
Efficiency
Output Specifications
PARAMETER
Output Power
Output DC Adjustability:
Overshoot
Load Transient
Turn-On Time from AC ON
Turn-On Delay
Hold-Up Time
Remote Sense
Interface Signals and Internal Protection
PARAMETER
Overvoltage Protection
Short Circuit Protection
103354D Rev AB1, 06-FEB-09
With convection cooling (-3300 25 W).
With forced-air cooling (-3300 41 W).
CONDITIONS/DESCRIPTION
Single-phase continuous input range.
Consult factory.
AC input.
At 115 VAC input.
Internally limited.
Internally limited.
Internally located AC input line fuse rated at F, 250 V, 3.15 A.
At Max Power, -3300 60% nominal.
CONDITIONS/DESCRIPTION
Adjustability of Vo1 (Vo2/Vo3 are not adjustable).
Vo1, Vo2, or Vo3 deviation due to a 50 to 100% load change
at a rate of 1A/µs.
Time required for output voltage to reach within regulation after initial application
of AC input.
Time required for output voltage to rise from 10% to 90%.
At 40 W, 115 VAC
Total compensation for cable losses on Vo1.
(Remote Sense is not available for Vo2 or Vo3)
CONDITIONS/DESCRIPTION
Main output.
Fully-protected against output short circuit.
Page 2 of 6
Vin = 115 VAC, Max Power, 25 °C.
Vin = 230VAC, Max Power, 25 °C.
See Model Selection Table
See Model Selection Table
BLP55 AC-DC Series Data Sheet
3.3V:
12V:
24V:
48V:
5V:
-5%, +10%
13.8
27.6
52.8
MIN
MIN
MIN
3.8
5.7
85
47
100-250
50/60
NOM
NOM
NOM
18
36
70
20
1
www.power-one.com
16.2
32.4
56.4
MAX
264
MAX
500
MAX
1.5
4.5
6.8
63
40
55
±3
20
55 Watts
5
Of Nom
Watts
UNITS
A
UNITS
UNITS
VAC
A
A
Sec
mV
ms
ms
Hz
RMS
%
%
%
V
PK
PK

Related parts for BLP55-3300G