S82R-6521 Omron, S82R-6521 Datasheet - Page 2

no-image

S82R-6521

Manufacturer Part Number
S82R-6521
Description
POWER SPPLY SWITCHING 5/12V 2/2A
Manufacturer
Omron
Series
S82Rr
Datasheet

Specifications of S82R-6521

Voltage - Output
5V, 12V
Number Of Outputs
2
Power (watts)
50W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
200 ~ 240VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 3A
2nd Output
12 VDC @ 3A
Size / Dimension
4.41" L x 6.34" W x 1.57" H (112mm x 161mm x 40mm)
Power (watts) - Rated
50W
Operating Temperature
-10°C ~ 50°C
Efficiency
68%
Approvals
CSA, UL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
S82R6521
Specifications
■ Characteristics
Note: 1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal
Efficiency (typ.)
Input
Output
Ancillary
function
Others
2. These Power Supplies do not comply with safety standards if a DC power supply is used.
3. Defined with a 100% load at the rated input voltage (100 or 200 VAC).
4. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than 5% of the voltage adjustment range. When
5. Refer to Overload Protection on page 4 for details.
6. Weights are given for the covered type.
temperature of the Power Supply may result in ignition or burning.
adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged.
Voltage
(See note 1.)
Frequency (See note 1.)
Current (See note 3.)
Leakage current
(See note 3.)
Inrush current (See note 3.) 30 A max. (for a cold start at 25°C)
Noise filter
Voltage accuracy
Voltage adjustment range
(See note 4.)
Ripple (See note 3.)
Input variation influence
Load variation influence
Temperature variation
influence
Startup time
Hold up time (See note 3.)
Overload protection
(See note 5.)
Overvoltage protection
Operating temperature
Storage temperature
Operating humidity
Dielectric strength
Insulation resistance
Vibration resistance
Shock resistance
Output indicator
Approved
standards
Weight (See note 6.)
http://www.ia.omron.com/
AC
DC
UL
CSA
Power rating
Input
68% min. (depending on model)
85 to 132 V
110 to 170 V (See note 2.)
50/60 Hz (47 to 450 Hz)
1.1 A max.
0.5 mA max.
Yes
V
Fixed except for 5-V output which can be adjusted by ±5% (with V. ADJ)
2% (p-p) max.
0.4% max. (at 85 to 132 V input, 100% load)
V
0.05%/°C max. (at rated input/output)
200 ms max. (Up to 90% of output voltage at rated input and output)
20 ms min.
105% min. of rated current, voltage drop, automatic reset
No
Refer to the derating curve in Engineering Data (with no icing or condensation).
−25°C to 65°C
25% to 85% (storage humidity: 20% to 90%)
2.0 kVAC, 50/60 Hz, for 1 minute (between input terminals and output terminals/PE terminal)
100 MΩ min. (between output terminals and input terminals/PE terminal at 500 VDC)
10 to 55 Hz, 0.75 mm single amplitude for 2 hours each in X, Y, and Z directions
294 m/s
V1 output indicator only (color: red)
UL1012
E.B.1402C
400 g max.
1
1
: 3.5% max. V
: 0.8% max. (at rated input, 10% to 100% load) V
30 W
2
, 3 times each in ±X, ±Y, ±Z directions
2
1.4 A max.
500 g max.
: 5% max. (with input, load, and temperature within permissible fluctuation ranges)
100 V input
50 W
2 A max.
550 g max.
75 W
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
170 to 264 V
Not available
0.7 A max.
1 mA max.
60 A max. (for a cold start at 25°C)
0.4% max. (at 170 to 264 V input, 100% load)
400 g max.
2
: 2% max.
30 W
0.8 A max.
500 g max.
200 V input
50 W
1.1 A max.
550 g max.
S82R
75 W
2

Related parts for S82R-6521