SWT30-522 TDK Corporation, SWT30-522 Datasheet
SWT30-522
Specifications of SWT30-522
SWT30522
Related parts for SWT30-522
SWT30-522 Summary of contents
Page 1
... Output Current (Peak) /Model Output Current (Peak) /Model Output Current (Peak) /Model Output Current (Peak) /Model Output Current (Peak) /Model Output Current (Peak) /Model +5V 2A (3A) 2A (3A) −5V − 0.3A (−) +12V 1.5A (3A) 1.5A (3A) SWT30-522 SWT30-525 −12V 0.3A (−) − +15V − − −15V − ...
Page 2
... Over voltage clamping by zener diode. (*9) At standard mounting method, Fig B. (*10) Peak current operation is less than 10 sec. with duty factor less than 30%. In addition, it does not have to satisfy the total regulation specification. A-274 SWT30 Specifications MODEL SWT30-522 (*2) V AC85 - 265 (Continuously) / DC110 - 340 (*2) Hz (*1) % ...
Page 3
... SWT 30 【SWT30】 LEAD CUT LESS THAN 3.0 3.0MAX 30.5±0.5 PCB MATERIAL GLASS COMPOSITE : CEM-3 NOTES A : THE 4-φ3.5 HOLES ARE CUSTOMER'S CHASSIS MOUNTING HOLES. ALL MUST BE SCREWED IN ORDER TO CONFORM THE VIBRATION SPEC MODEL NAME, NORMAL OUTPUT VOLTAGE AND AVERAGE OUTPUT CURRENT ARE SHOWN HERE IN ACCORANCE WITH THE SPECIFICATIONS ...
Page 4
SWT 40 SWT40 ITEMS/UNITS Voltage Range Frequency Input Efficiency (typ) Current (100/200VAC)(typ) (*1) A Inrush Current (100/200VAC)(typ) Nominal Voltage Minimum Current Maximum Current Maximum Peak Current (*10) A Maximum Peak Power Maximum Line Regulation (*3)(*4) Output Maximum Load Regulation (*3)(*5) ...
Page 5
SWT 40 【SWT40】 LEAD CUT LESS THAN 3.0 3.0MAX 35.6±1 PCB MATERIAL GLASS COMPOSITE : CEM-3 NOTES A : THE 4-φ3.5 HOLES ARE CUSTOMER'S CHASSIS MOUNTING HOLES. ALL MUST BE SCREWED IN ORDER TO CONFORM THE VIBRATION SPEC ...
Page 6
SWT 65 ITEMS/UNITS Voltage Range Frequency Input Efficiency (typ) Current (100/200VAC)(typ) (*1) A Inrush Current (100/200VAC)(typ) Nominal Voltage Minimum Current Maximum Current Maximum Peak Current Maximum Power Maximum Line Regulation (*3)(*4) Output Maximum Load Regulation (*3)(*5) Temperature Coefficient (*3)(*6) Maximum ...
Page 7
SWT 65 【SWT65】 LEAD CUT LESS THAN 3.0 3.0MAX SEE NOTE A 45.0±1 PCB MATERIAL GLASS COMPOSITE : CEM-3 NOTES A : THE 4-φ3.5 HOLES ARE CUSTOMER'S CHASSIS MOUNTING HOLES. ALL MUST BE SCREWED IN ORDER TO CONFORM THE VIBRATION ...
Page 8
SWT 100 ITEMS/UNITS Voltage Range Frequency Input Efficiency (typ) Current (100/200VAC)(typ) (*1) A Inrush Current (100/200VAC)(typ) (*10) A Nominal Voltage Minimum Current Maximum Current Maximum Peak Current Maximum Power Maximum Line Regulation (*3)(*4) mV Output Maximum Load Regulation (*3)(*5) mV ...
Page 9
SWT 100 【SWT100】 LEAD CUT LESS THAN 3.0 3.0MAX 44.96±1 PCB MATERIAL GLASS COMPOSITE : CEM-3 NOTES A : THE 5 φ3.5 HOLES ARE CUSTOMER'S CHASSIS MOUNTING HOLES. ALL MUST BE SCREWED IN ORDER TO CONFORM THE VIBRATION SPEC. B ...
Page 10
... L Input 85-265VAC N FG ● Circuit mode and switching frequency Switching circuit:Flyback topology SWT30, SWT40…100kHz(Fixed) ● Fuse rating SWT30, SWT40…2. 5A 【SWT65】 L Input 85-132VAC /170-265VAC N FG ● Circuit mode and switching frequency Switching circuit:Flyback topology ...
Page 11
... SWT SERIES Circuit for Measuring Performances 【SWT30, SWT40】 150mm Wire material: CN2 AWG#18 1 + +5V +5V 3 + GND GND 5 + C6 −V 6 Measurement point for V ripple Measurement point of output voltage 【SWT65】 150mm Wire material: CN2 AWG#18 +5V 1 +5V 2 + C2 GND ...
Page 12
... Connect FG terminal of input connector and mountale JWT FG to ground terminal of the equipment. ● Use the input/output connector housing, terminal pin as MTW specified in outline drawing. RKE SWT30, 40 Terminal Explanation RKY SWT30, 40 Component Side RTW Component Side Input SWT UNA VS SWT65 Terminal Explanation VS-P ...
Page 13
... Component Side Input 2. Explanation of Functions and Precautions Input Voltage Range Input voltage range of SWT30, SWT40 and SWT100 is si- ngle phase 85-265VAC (47-63Hz) or DC110-340V. Input voltage range for SWT65 is 85-132VAC or 170- 265VAC. Do not switch input voltage from 85-132VAC directly to 170-265VAC, as may cause power supply dam- aged ...
Page 14
... Please use the mounting hole and insert the spacer (MAX RKY φ6.0mm) of height over 8mm to lift the unit. The vibration spec is the value taken when the unit is raised by 8mm RTW specers. SWT30,SWT40,SWT65‥‥ SWT100‥‥5 pcs(φ3.5mm) SWT UNA VS VS-P ...
Page 15
... SWT65 8,000uF SWT100 50,000uF ● Check whether output current are more than minimum output current. The output voltage of all channel are stabilized when CH1 (all model) and CH2 (only SWT30, 40) are more than minimum output current. Model Fuse Rating 2.5A 3.15A 5A Maximum capacitance CH2 ( ...