GPC41-15 SL Power Electronics Manufacture of Condor/Ault Brands, GPC41-15 Datasheet - Page 2

no-image

GPC41-15

Manufacturer Part Number
GPC41-15
Description
POWER SUPPLY SWITCHER 40W 15V
Manufacturer
SL Power Electronics Manufacture of Condor/Ault Brands
Series
GPC41r
Datasheet

Specifications of GPC41-15

Rohs Status
RoHS non-compliant
Voltage - Output
15V
Number Of Outputs
1
Power (watts)
41W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
15 VDC @ 2.7A
Size / Dimension
4" L x 2" W x 1.5" H (101.6mm x 50.8mm x 38.1mm)
Power (watts) - Rated
40W
Operating Temperature
0°C ~ 50°C
Efficiency
77%
Approvals
CE, CSA, EN, IEC, TUV, UL
Load Regulation
0.75%
3rd Output
-
2nd Output
-
4th Output
-
Note:
A. Units should be allowed to warm up/operate under non-condensing conditions before application of power. Derate output
current and total output power by 2.5% per °C above 50°C. For operation in a confined space, moving air may be required. Under
all conditions, the cooling vs. load profile should be such that heat sinks and/or heatsink temperatures do not exceed 90 °C for
extended periods.
B. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes, total 6 shocks.
C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating
and 1 hr./axis non-operating.
SL Power Electronics Corp., 6050 King Drive, Bldg.A, Ventura, CA, 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 Email: info@slpower.com. Rev. 4/08.
Data Sheet © 2008 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication.
However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
Commercial
Model
GPC41-5
GPC41-12
GPC41-15
GPC41-24
GPC41-28
ENVIRONMENTAL SPECIFICATIONS
Temperature (A)
Humidity (A)
Shock (B)
Altitude
Vibration (C)
GPC41/GPM41 MECHANICAL SPECIFICATIONS
Add “G” suffix to model number for RoHS compliant model.
3
Medical
Model
GPM41-5
GPM41-12
GPM41-15
GPM41-24
Output
5.1 V
12 V
15 V
24 V
28 V
OPERATING
See individual specs.
0 to 95% RH
20 g
-500 to 10,000 ft
1.5 g
pk
Current
rms’
6.0 A
3.3 A
2.7 A
1.7 A
1.4 A
0.003 g
2
/Hz
Minimum
Load
0.15
0.03
0.03
0.01
0.01
3
NON-OPERATING
-40 to +85°C
0 to 95% RH
40 g
-500 to 40,000 ft
5 g
Regulation
rms’
pk
0.75%
0.75%
0.75%
0.75%
0.75%
Load
0.026 g
2
/Hz
Initial Setpoint
Tolerance
2%
2%
2%
2%
2%
6.2 ± 0.6 V
14 ± 1.0 V
19 ± 1.5 V
34 ± 2.8 V
28± 2.5 V
Setpoint
OVP
Ripple and
Noise
1%
1%
1%
1%
1%

Related parts for GPC41-15